The AOD 1 is used for oxidative decomposition of solid and liquid organic and partially unorganic samples under pressure in…
sold out
Rp

The AOD 1 is used for oxidative decomposition of solid and liquid organic and partially unorganic samples under pressure in a closed system 
The system consists of: 
AOD 1.1 Decomposition vessel, C 48 Oxygen station, AOD 1.2 External ignition unit, AOD 1.11 Control standard (50 ml) 
– Quantitative decomposition of all halogens, sulfur, as well as volatile metals, e.g. As and Hg 
– Absorption of the combustion products in an aqueous medium 
– Catalytic support of the oxidation process with auto-regenerating catalytic insidewalls of the decomposition vessel 
– Pressure vessel of high-grade stainless steel 
– Decomposition temperature up to 1200 °C 
– Max. operating pressure during decomposition 195 bar 
– Decomposition time < 3 min 
– The decomposition vessel can be changed over to use combustible crucibles C 14 
– Control standards for Cl, S ( AOD 1.11) , F and Br ( AOD 1.12 accessory ) 
– Introduction of the combustion gases into the absorption solution via venting station C 7030 

The principal and function is based on the method of the combustion in the bomb calorimeter and validated according 
DIN 51577, part 1 dt. 1982 
other relevants validations are: 
– DIN / EN 14582, determination characteristics of waste, halogene and sulfur content 
– DIN 51527 , Testing of solid samples, determination for the clorine content 

Produk Pernah Dilihat

Detail Produk

Kategori : LAIN-LAIN

The AOD 1 is used for oxidative decomposition of solid and liquid organic and partially unorganic samples under pressure in a closed system 
The system consists of: 
AOD 1.1 Decomposition vessel, C 48 Oxygen station, AOD 1.2 External ignition unit, AOD 1.11 Control standard (50 ml) 
– Quantitative decomposition of all halogens, sulfur, as well as volatile metals, e.g. As and Hg 
– Absorption of the combustion products in an aqueous medium 
– Catalytic support of the oxidation process with auto-regenerating catalytic insidewalls of the decomposition vessel 
– Pressure vessel of high-grade stainless steel 
– Decomposition temperature up to 1200 °C 
– Max. operating pressure during decomposition 195 bar 
– Decomposition time < 3 min 
– The decomposition vessel can be changed over to use combustible crucibles C 14 
– Control standards for Cl, S ( AOD 1.11) , F and Br ( AOD 1.12 accessory ) 
– Introduction of the combustion gases into the absorption solution via venting station C 7030 

The principal and function is based on the method of the combustion in the bomb calorimeter and validated according 
DIN 51577, part 1 dt. 1982 
other relevants validations are: 
– DIN / EN 14582, determination characteristics of waste, halogene and sulfur content 
– DIN 51527 , Testing of solid samples, determination for the clorine content 