Gas Control Spray Chamber Metal Glass Spray Safety System Czerny-Turner grating monochromator Anti-corrosive plastic sprayed chamber 10cm single slot all-titanium…
sold out
Rp
  • Gas Control
  • Spray Chamber Metal Glass Spray
  • Safety System
  • Czerny-Turner grating monochromator
  • Anti-corrosive plastic sprayed chamber
  • 10cm single slot all-titanium burner
Wavelength Range 190-900 nm
Wavelength Accuracy Better than ±0.25 nm
Spectral Bandwidth 0.1, 0.2, 0.4, 1.2 nm
Resolution Less than 30%
Baseline Stability 0.004A/30min
Flame Temperature 2300-2950°C
Grating 1800 lines/mm
Focal Length 277 mm
Blazed Wavelength 250 nm
Concentration and Detection Limit Cu: Characteristic concentration≤0.025mg/L Detection limit≤0.006mg/L; Ba: Characteristic concentration ≤ 0.22mg/L; Al: Characteristic concentration ≤ 0.4mg/L;
Graphite Furnace Temp. Range RT-3000°C
Graphite Furnace Heating Rate 2000°C/s
Graphite Furnace Tube Dimensions 28×8 mm
Graphite Furnace Character Mass Cd≤0.5 ×10-12g, Cu≤5 ×10-12g, Mo≤1×10-11g
Graphite Furnace Precision Cd≤3%, Cu≤3%, Mo≤4%
Graphite Furnace Overall Dimension 420x420x460 mm
Autosampler Overall Dimension None
Graphite Furnace Weight (Net/Gross) 50 kg
Autosampler Weight (Net/Gross) None
Overall Dimension 1020x490x540 mm
Weight 80 kg

Detail Produk

Kategori : AAS
  • Gas Control
  • Spray Chamber Metal Glass Spray
  • Safety System
  • Czerny-Turner grating monochromator
  • Anti-corrosive plastic sprayed chamber
  • 10cm single slot all-titanium burner
Wavelength Range 190-900 nm
Wavelength Accuracy Better than ±0.25 nm
Spectral Bandwidth 0.1, 0.2, 0.4, 1.2 nm
Resolution Less than 30%
Baseline Stability 0.004A/30min
Flame Temperature 2300-2950°C
Grating 1800 lines/mm
Focal Length 277 mm
Blazed Wavelength 250 nm
Concentration and Detection Limit Cu: Characteristic concentration≤0.025mg/L Detection limit≤0.006mg/L; Ba: Characteristic concentration ≤ 0.22mg/L; Al: Characteristic concentration ≤ 0.4mg/L;
Graphite Furnace Temp. Range RT-3000°C
Graphite Furnace Heating Rate 2000°C/s
Graphite Furnace Tube Dimensions 28×8 mm
Graphite Furnace Character Mass Cd≤0.5 ×10-12g, Cu≤5 ×10-12g, Mo≤1×10-11g
Graphite Furnace Precision Cd≤3%, Cu≤3%, Mo≤4%
Graphite Furnace Overall Dimension 420x420x460 mm
Autosampler Overall Dimension None
Graphite Furnace Weight (Net/Gross) 50 kg
Autosampler Weight (Net/Gross) None
Overall Dimension 1020x490x540 mm
Weight 80 kg