Auto ELISA Processor (BIOBASE2000)
Auto ELISA Processor (BIOBASE2000)

Auto ELISA Processor (BIOBASE2000)

5 (1 votes)

share

①.4 microplates,2 pipetting probes ②. 192 sample positions , 96 dilution positions,23 reagent   positions, 16 common reagent positions,48 QC positions. ③. All…
sold out
Rp

①.4 microplates,2 pipetting probes

②. 192 sample positions , 96 dilution positions,23 reagent   positions, 16 common reagent positions,48 QC positions.

③. All sample & reagent positions can be editable.

Model  BIOBASE2000
Sample pipetting unit  Sample rack  24 sample tubes/rack, at most 23 racks
 Primary sample tubes  11.5-13mm
 Pipetting  8ul~1000ul, (10ul) CV<5%
 Time to dispense  12 minutes adding 96 samples
 Dispensing system  1 aspirating-dispensing probe with X-Y-Z movement;dilution system with a syringe of 1000ul, continuous flow washing station.
Reagent pipetting unit  Reagent racks  2 reagent tanks(60ml)/ rack, at most 23 racks
 QC racks  24 positions/QC rack, at most 23 racks
 Pipetting  8ul~1000ul,1ul stepping
 pipetting precision  (100ul )CV≤0.5%
 Time to dispense  3 minutes(typical)^100ul of 96 reagents to plate from reagent bottle
Washing unit  Programmable  Yes(options & parameters)
 Wash containers  3 wash buffers at 2.0L,1 wash buffers at 5.0L,with level-sensing
 Waste containers  25L with waste full sensor
 Washing system  two 8 nozzle manifolds, one to dispense and the other one to aspirate
 Washing residual  <2μl
Reading unit  Reading system  8 independent photometric channels with mono and bichromatic reading capability
 Photometric range  0.000 ~3.000 OD
 Spectral range  400-700nm
 Optical filters  2 precision filters (450and 630nm); 2 more on request (4 filters max, 405 nm, 450 nm, 492 nm and 630 nm)
 Reading inaccuracy  inaccuracy±1% from 0.000 to 1.500 OD, ±2% from 1.500 to 3.000 OD
Incubation unit  Incubators  4 independent units
 Programmable  Yes
 Temperature range  RT to 45 °C
 Temperature accuracy  ±0.5℃
 Temperature staility  ±0.5℃
Software unit  Software system  Windows 7/8/107 or above, LIS system available
 Function application  work list set up, patient reports and result filing; calibration curve storage for each  carried out test
 Data reduction  cut-off (qualitative)
Others  Power Supply  AC 110/220V±10%,50/60Hz,450W
 External Size(W*D*H)  1235*710*880mm
 PackageSize(W*D*H)  1370*850*1439mm
 Gross Weight  220kg

Produk Pernah Dilihat

Detail Produk

Kategori : ALAT LABORATORIUM

①.4 microplates,2 pipetting probes

②. 192 sample positions , 96 dilution positions,23 reagent   positions, 16 common reagent positions,48 QC positions.

③. All sample & reagent positions can be editable.

Model  BIOBASE2000
Sample pipetting unit  Sample rack  24 sample tubes/rack, at most 23 racks
 Primary sample tubes  11.5-13mm
 Pipetting  8ul~1000ul, (10ul) CV<5%
 Time to dispense  12 minutes adding 96 samples
 Dispensing system  1 aspirating-dispensing probe with X-Y-Z movement;dilution system with a syringe of 1000ul, continuous flow washing station.
Reagent pipetting unit  Reagent racks  2 reagent tanks(60ml)/ rack, at most 23 racks
 QC racks  24 positions/QC rack, at most 23 racks
 Pipetting  8ul~1000ul,1ul stepping
 pipetting precision  (100ul )CV≤0.5%
 Time to dispense  3 minutes(typical)^100ul of 96 reagents to plate from reagent bottle
Washing unit  Programmable  Yes(options & parameters)
 Wash containers  3 wash buffers at 2.0L,1 wash buffers at 5.0L,with level-sensing
 Waste containers  25L with waste full sensor
 Washing system  two 8 nozzle manifolds, one to dispense and the other one to aspirate
 Washing residual  <2μl
Reading unit  Reading system  8 independent photometric channels with mono and bichromatic reading capability
 Photometric range  0.000 ~3.000 OD
 Spectral range  400-700nm
 Optical filters  2 precision filters (450and 630nm); 2 more on request (4 filters max, 405 nm, 450 nm, 492 nm and 630 nm)
 Reading inaccuracy  inaccuracy±1% from 0.000 to 1.500 OD, ±2% from 1.500 to 3.000 OD
Incubation unit  Incubators  4 independent units
 Programmable  Yes
 Temperature range  RT to 45 °C
 Temperature accuracy  ±0.5℃
 Temperature staility  ±0.5℃
Software unit  Software system  Windows 7/8/107 or above, LIS system available
 Function application  work list set up, patient reports and result filing; calibration curve storage for each  carried out test
 Data reduction  cut-off (qualitative)
Others  Power Supply  AC 110/220V±10%,50/60Hz,450W
 External Size(W*D*H)  1235*710*880mm
 PackageSize(W*D*H)  1370*850*1439mm
 Gross Weight  220kg