Bromine, Chlorine, Cyanuric Acid, Iron Iodine and pH Portable Photometer Hanna Instruments HI 96101 Description:   CAL CHECK™ User calibration…
sold out
Rp
Bromine, Chlorine, Cyanuric Acid, Iron Iodine and pH Portable Photometer
Hanna Instruments HI 96101
Description:

 

  • CAL CHECK™
  • User calibration
  • Certified calibration and verification standards
  • BEPS (Battery Error Prevention System)
  • TIMER function
  • Auto shut-off
  • GLP Features
    The HI 96101 measures Bromine, Free and Total Chlorine, Cyanuric Acid, Iron, Iodine and pH content in water and wastewater samples.
    The reagents are in powder and liquid form depending on the parameter and they are supplied in dropper bottles and packets.
    This multiparameter photometer can save time and money. If you need a simple, but professional meter measuring the most important
    constituents of water, especially in pools and spas, then HI 96101 has been designed for you.
    The meter uses an exclusive positive-locking system to ensure that the cuvette is in the same place every time it is placed into the
    measurement cell.
    The cuvette has a very important role because it is an optical element and thus requires particular attention. It is important that both the
    measurement and calibration (zeroing) cuvettes are optically identical to provide the same measuring conditions.
    Specifications:
    Range
    Bromine
    0.00 to 10.00 mg/L (ppm)
    Cl, Free
    0.00 to 5.00 mg/L (ppm)
    Cl, Total
    0.00 to 5.00 mg/L (ppm)
    CYA
    0 to 80 mg/L (ppm)
    Iodine
    0.0 to 12.5 mg/L (ppm)
    Iron LR
    0.00 to 1.60 mg/L
    pH
    6.5 to 8.5 pH
    Resolution
    Bromine
    0.01 mg/L (ppm)
    Chlorine
    0.01 mg/L under 3.50 mg/L;
    0.10 mg/L above 3.50 mg/L
    CYA
    1 mg/L (ppm)
    Iron LR
    0.01 mg/L
    pH
    0.1 pH
    Accuracy @25°C
    Bromine
    ±0.08 mg/L ±3% of reading
    Chlorine
    ±0.03 mg/L ±3% of reading
    CYA
    ±1 mg/L ±15% of reading
    Iodine
    ±0.1 mg/L ±5% of reading
    Iron LR
    ±0.01 mg/L ±8% of reading
    pH
    ±0.1 pH
    Light Source
    tungsten lamp
    Light Detector
    silicon photocell with narrow band interference filter @ 525 nm
    Power Supply
    9V battery
    Auto-off
    after ten minutes of non-use in measurement mode; after one hour
    of non-use in calibration mode; with last reading reminder
    Dimensions
    192 x 104 x 69 mm (7.6 x 4.1 x 2.7″)
    Weight
    360 g (12.7 oz.)
    Method
    Bromine
    adaptation of the EPA, DPD method
    Chlorine
    Adaptation of the USEPA method and Standard Method 4500-Cl G
    CYA
    adaptation of the turbidimetric method
    Iodine
    adaptation of the EPA, DPD method
    Iron LR
    adaptation of the TPTZ method
    pH
    Phenol Red method
    Environment
    0 to 50°C (32 to 122°F); RH max 95% non-condensing

 

Detail Produk

Kategori : LAIN-LAIN
Bromine, Chlorine, Cyanuric Acid, Iron Iodine and pH Portable Photometer
Hanna Instruments HI 96101
Description:

 

  • CAL CHECK™
  • User calibration
  • Certified calibration and verification standards
  • BEPS (Battery Error Prevention System)
  • TIMER function
  • Auto shut-off
  • GLP Features
    The HI 96101 measures Bromine, Free and Total Chlorine, Cyanuric Acid, Iron, Iodine and pH content in water and wastewater samples.
    The reagents are in powder and liquid form depending on the parameter and they are supplied in dropper bottles and packets.
    This multiparameter photometer can save time and money. If you need a simple, but professional meter measuring the most important
    constituents of water, especially in pools and spas, then HI 96101 has been designed for you.
    The meter uses an exclusive positive-locking system to ensure that the cuvette is in the same place every time it is placed into the
    measurement cell.
    The cuvette has a very important role because it is an optical element and thus requires particular attention. It is important that both the
    measurement and calibration (zeroing) cuvettes are optically identical to provide the same measuring conditions.
    Specifications:
    Range
    Bromine
    0.00 to 10.00 mg/L (ppm)
    Cl, Free
    0.00 to 5.00 mg/L (ppm)
    Cl, Total
    0.00 to 5.00 mg/L (ppm)
    CYA
    0 to 80 mg/L (ppm)
    Iodine
    0.0 to 12.5 mg/L (ppm)
    Iron LR
    0.00 to 1.60 mg/L
    pH
    6.5 to 8.5 pH
    Resolution
    Bromine
    0.01 mg/L (ppm)
    Chlorine
    0.01 mg/L under 3.50 mg/L;
    0.10 mg/L above 3.50 mg/L
    CYA
    1 mg/L (ppm)
    Iron LR
    0.01 mg/L
    pH
    0.1 pH
    Accuracy @25°C
    Bromine
    ±0.08 mg/L ±3% of reading
    Chlorine
    ±0.03 mg/L ±3% of reading
    CYA
    ±1 mg/L ±15% of reading
    Iodine
    ±0.1 mg/L ±5% of reading
    Iron LR
    ±0.01 mg/L ±8% of reading
    pH
    ±0.1 pH
    Light Source
    tungsten lamp
    Light Detector
    silicon photocell with narrow band interference filter @ 525 nm
    Power Supply
    9V battery
    Auto-off
    after ten minutes of non-use in measurement mode; after one hour
    of non-use in calibration mode; with last reading reminder
    Dimensions
    192 x 104 x 69 mm (7.6 x 4.1 x 2.7″)
    Weight
    360 g (12.7 oz.)
    Method
    Bromine
    adaptation of the EPA, DPD method
    Chlorine
    Adaptation of the USEPA method and Standard Method 4500-Cl G
    CYA
    adaptation of the turbidimetric method
    Iodine
    adaptation of the EPA, DPD method
    Iron LR
    adaptation of the TPTZ method
    pH
    Phenol Red method
    Environment
    0 to 50°C (32 to 122°F); RH max 95% non-condensing

 