Gas Chromatograph 1
Gas Chromatograph 1

Gas Chromatograph 1

5 (1 votes)

share

Features: 1. 7-inch LCD display indicates temperature, gas flow and heating curve. 2. Self-test function and automatic fault recognition function.…
sold out
Rp

Features:

1. 7-inch LCD display indicates temperature, gas flow and heating curve.

2. Self-test function and automatic fault recognition function.

3. 8 pcs external extension interfaces can connect with control valve.

4. Equipped with a flame ionization detector (FID) which adopts APC control.

5. Multi-core and 32-bit embedded hardware system ensures the reliable operation.

6. Synchronous external trigger function and the external signal (auto sampler, hot analytical instruments, etc.) can start the equipment and workstation software at the same time.

7. With chromatography workstation software to process data.

Model BK-GC112A
Oven Temp. Range RT+5℃~400℃
Temp. Accuracy ±0.02℃
Temp. Program 9-phase/ 10 platform
Max Temp. Heating Rate 60℃/min
Sample injector Temp. Range RT+7℃~420℃
Column or split injector can be installed.
Split mode can directly set the split ratio.
Constant pressure mode.
A separate injection system is connected.
Detector Temp. Range RT+7℃~420℃
Hydrogen Flame Ionization Detector (FID) Logarithmic amplifier
High voltage switch control
Baseline signal display
Ignition coil control
Detection limit:≤3*10-12g/s

(Sample: n-hexadecane)

Dynamic range: 107
Thermal Conductivity Detector (TCD)

(Optional)

Bridge voltage switch control
Bridge current setting: 0-220mA
Sensitivity: 6000mv.ml/mg
Dynamic range: 105
Power Supply AC220V±10%, 50/60Hz
Standard Accessory FID detector, Capillary injection system, Chromatography workstation software.
Optional Accessory TCD detector, Chromatographic column, Gas purifier.
Package Size (W*D*H) 1020*660*740mm
Gross Weight 82kg

Produk Pernah Dilihat

Detail Produk

Kategori : ALAT LABORATORIUM

Features:

1. 7-inch LCD display indicates temperature, gas flow and heating curve.

2. Self-test function and automatic fault recognition function.

3. 8 pcs external extension interfaces can connect with control valve.

4. Equipped with a flame ionization detector (FID) which adopts APC control.

5. Multi-core and 32-bit embedded hardware system ensures the reliable operation.

6. Synchronous external trigger function and the external signal (auto sampler, hot analytical instruments, etc.) can start the equipment and workstation software at the same time.

7. With chromatography workstation software to process data.

Model BK-GC112A
Oven Temp. Range RT+5℃~400℃
Temp. Accuracy ±0.02℃
Temp. Program 9-phase/ 10 platform
Max Temp. Heating Rate 60℃/min
Sample injector Temp. Range RT+7℃~420℃
Column or split injector can be installed.
Split mode can directly set the split ratio.
Constant pressure mode.
A separate injection system is connected.
Detector Temp. Range RT+7℃~420℃
Hydrogen Flame Ionization Detector (FID) Logarithmic amplifier
High voltage switch control
Baseline signal display
Ignition coil control
Detection limit:≤3*10-12g/s

(Sample: n-hexadecane)

Dynamic range: 107
Thermal Conductivity Detector (TCD)

(Optional)

Bridge voltage switch control
Bridge current setting: 0-220mA
Sensitivity: 6000mv.ml/mg
Dynamic range: 105
Power Supply AC220V±10%, 50/60Hz
Standard Accessory FID detector, Capillary injection system, Chromatography workstation software.
Optional Accessory TCD detector, Chromatographic column, Gas purifier.
Package Size (W*D*H) 1020*660*740mm
Gross Weight 82kg