Features Top of the Page The light source performs an automatic interchange, selectable within the working range of the light…
sold out
Rp

Features

Top of the Page

  • The light source performs an automatic interchange, selectable within the working range of the light source. Fully automated operations: automatic change-over between W lamp and D2 lamp; automatic filter changing; automatic wavelength calibration; W lamp and D2 lamp On/Off auto-control; automatic zero and 100%T adjustment.

  • Automatic peak-picking; easy operations for replacing W lamp and D2 lamp.

  • Friendly interface; abundant operation prompts; convenient and fast operations.

  • Blue LCD display module with 320×240 large screen.

  • Economical embedded single-chip micro-processor control system.

  • Rich and powerful functions:

    • Five basic measurement modes: WL Scan (A, T, E), Photometric measurement (Fixed WL measurement, A, T), Quantitation (Concentration Measurement, A, C), Time Scan (Kinetics Measurement, A, T), Real Time Measurement (A, T, C, E);
    • Powerful spectrum processing functions: Spectrum Save, Spectrum Load, Peak-Valley Pick, Derivative Spectrum, Data Printing at Intervals, Activity Calculation, Cursor locating, Spectrum Zooming, A-T Conversion, Spectrum Printing;
    • Data Processing functions: data save, data looking up, data deleting and data printing, etc.
    • Cell error can be corrected;
    • Parameters can be saved for a long time after turning off the instrument;
    • Spectrum and data can be stored when sudden power failure occurs;
    • Spectrum and data can be sent to computer via RS-232 interface or USB interface.

     

Software Specifications

Such operations as photometry measurement, spectrum measurement, quantitation measurement and kinetic measurement are offered in UV-Win Windows applications.

Multi-wavelengths photometric measurement at up to 10 wavelengths with the arithmetic calculation according to the user-entered formula.

Up to 10 spectra and time-course curves can be measured and recalled in memory with data-handling of arithmetic calculation, logarithmic calculation, reciprocal calculation, smooth, derivate (1st ~ 4th), Abs to/from %T conversion and peak pick.

Up to 24 standards can be entered and measured for the fit of calibration curve with order to 1st ~ 4th. Offered are the quantitation methods of single wavelength, two-wavelength, coefficient two-wavelength, three wavelength and 1st ~ 4th derivatives.

Kinetic measurement can monitor the changes of absorbance and transmittance against time course at 10 different wavelengths. This module allows flexibility in manipulation and data display.

With the Windows clipboard, the measured data and graphics can be copied to other applications software for reports. Also offered are filing functions, display functions, and others (such as auto file and repeat measure/scan etc.).

Included Accessories

Top of the Page

  • 4 square optical cells 10mm.
  • 2 square quartz cells 10 mm with lid
  • Dust cover
  • 1 Software
  • 1 Software Manual
  • 1 Instruction Manual
  • 1 Power cable
  • 1 PC cable
  • 1 USB cable

Top of the Page

Technical Specifications

Top of the Page

– Optical System: Single Beam
– Wavelength range: 190-1100nm
– Spectral Bandwidth: 2nm
– Wavelength Accuracy: ±0.5nm
– Wavelength Reproducibility: 0.2nm
– Photometric Accuracy: ±0.5%T (0~100%T)
±0.002A (0~0.5A)
±0.004A (0.5A ~1A)
– Photometric Reproducibility: 0.2%T
– Range of Transmittance: (0%T~220%T)
– Range of Absorbance: -.301A~3.000A
– Photometric Method: T,A,(-0.3-3A),C,E
– Stray Light: ≤0.1%T(NaI,220nm;NaNO2,340nm)
– Baseline Flatness: ±0.002A
– Stability: ≤0.002A/h (at 500nm, after warming up)
– Minimum Sampling Interval: 0.1nm
– Energy Range: 0.000V ~ 9.999V
– Noise: ±0.001A (at 500nm, after warming up)
– Slew Rate of Wavelength: 3000nm/min
– Scanning Speed: 1000 nm/min
– Standard Functionality: A,T
– Port: USB
– Detector: Silicon Photo-diode
– Display: 6 inches high light blue LCD
– Light Source:
Tungsten halogen lamp and D2 lamp
– Sample Chamber: 190mm x 125mm x 128mm
– DNA/RNA Measurement
Results Printout :
YES
– Software Support: YES
– Power: AC:220V/50Hz, 110V/60Hz,140W (Automatic)
– Dimensions: 530x410x210mm
– Net Weight:
18Kg.

 

Brosur

26. Labomed(USA)Spectro UV-Vis Auto UV-2650,The Spectro UV-2650 has a 2nm

Detail Produk

Kategori : LAIN-LAIN

Features

Top of the Page

  • The light source performs an automatic interchange, selectable within the working range of the light source. Fully automated operations: automatic change-over between W lamp and D2 lamp; automatic filter changing; automatic wavelength calibration; W lamp and D2 lamp On/Off auto-control; automatic zero and 100%T adjustment.

  • Automatic peak-picking; easy operations for replacing W lamp and D2 lamp.

  • Friendly interface; abundant operation prompts; convenient and fast operations.

  • Blue LCD display module with 320×240 large screen.

  • Economical embedded single-chip micro-processor control system.

  • Rich and powerful functions:

    • Five basic measurement modes: WL Scan (A, T, E), Photometric measurement (Fixed WL measurement, A, T), Quantitation (Concentration Measurement, A, C), Time Scan (Kinetics Measurement, A, T), Real Time Measurement (A, T, C, E);
    • Powerful spectrum processing functions: Spectrum Save, Spectrum Load, Peak-Valley Pick, Derivative Spectrum, Data Printing at Intervals, Activity Calculation, Cursor locating, Spectrum Zooming, A-T Conversion, Spectrum Printing;
    • Data Processing functions: data save, data looking up, data deleting and data printing, etc.
    • Cell error can be corrected;
    • Parameters can be saved for a long time after turning off the instrument;
    • Spectrum and data can be stored when sudden power failure occurs;
    • Spectrum and data can be sent to computer via RS-232 interface or USB interface.

     

Software Specifications

Such operations as photometry measurement, spectrum measurement, quantitation measurement and kinetic measurement are offered in UV-Win Windows applications.

Multi-wavelengths photometric measurement at up to 10 wavelengths with the arithmetic calculation according to the user-entered formula.

Up to 10 spectra and time-course curves can be measured and recalled in memory with data-handling of arithmetic calculation, logarithmic calculation, reciprocal calculation, smooth, derivate (1st ~ 4th), Abs to/from %T conversion and peak pick.

Up to 24 standards can be entered and measured for the fit of calibration curve with order to 1st ~ 4th. Offered are the quantitation methods of single wavelength, two-wavelength, coefficient two-wavelength, three wavelength and 1st ~ 4th derivatives.

Kinetic measurement can monitor the changes of absorbance and transmittance against time course at 10 different wavelengths. This module allows flexibility in manipulation and data display.

With the Windows clipboard, the measured data and graphics can be copied to other applications software for reports. Also offered are filing functions, display functions, and others (such as auto file and repeat measure/scan etc.).

Included Accessories

Top of the Page

  • 4 square optical cells 10mm.
  • 2 square quartz cells 10 mm with lid
  • Dust cover
  • 1 Software
  • 1 Software Manual
  • 1 Instruction Manual
  • 1 Power cable
  • 1 PC cable
  • 1 USB cable

Top of the Page

Technical Specifications

Top of the Page

– Optical System: Single Beam
– Wavelength range: 190-1100nm
– Spectral Bandwidth: 2nm
– Wavelength Accuracy: ±0.5nm
– Wavelength Reproducibility: 0.2nm
– Photometric Accuracy: ±0.5%T (0~100%T)
±0.002A (0~0.5A)
±0.004A (0.5A ~1A)
– Photometric Reproducibility: 0.2%T
– Range of Transmittance: (0%T~220%T)
– Range of Absorbance: -.301A~3.000A
– Photometric Method: T,A,(-0.3-3A),C,E
– Stray Light: ≤0.1%T(NaI,220nm;NaNO2,340nm)
– Baseline Flatness: ±0.002A
– Stability: ≤0.002A/h (at 500nm, after warming up)
– Minimum Sampling Interval: 0.1nm
– Energy Range: 0.000V ~ 9.999V
– Noise: ±0.001A (at 500nm, after warming up)
– Slew Rate of Wavelength: 3000nm/min
– Scanning Speed: 1000 nm/min
– Standard Functionality: A,T
– Port: USB
– Detector: Silicon Photo-diode
– Display: 6 inches high light blue LCD
– Light Source:
Tungsten halogen lamp and D2 lamp
– Sample Chamber: 190mm x 125mm x 128mm
– DNA/RNA Measurement
Results Printout :
YES
– Software Support: YES
– Power: AC:220V/50Hz, 110V/60Hz,140W (Automatic)
– Dimensions: 530x410x210mm
– Net Weight:
18Kg.

 