Model PH900P    pH Range -2.000~20.000pH    pH Accuracy ±0.002pH    Resolution 0.001, 0.01, 0.1pH, selectable    Calibration Points Up…
sold out
Rp
Model PH900P
   pH Range -2.000~20.000pH
   pH Accuracy ±0.002pH
   Resolution 0.001, 0.01, 0.1pH, selectable
   Calibration Points Up to 5 points
   Calibration Solutions USA(pH1.68/4.01/7.00/10.01/12.45), NIST(pH1.68/4.01/6.86/9.18/12.45), DIN(pH1.09/4.65/6.79/9.23/12.75)
   Ion Concentration Range 0.001~19999ppm, mg/L, mol/L (Depending on measuring range of Ion selective Electrode)
   Ion Concentration Accuracy ±0.5% Full Scale (Monovalent), ±1% Full Scale (Divalent)
   Calibration Points 2 to 5 points
   Calibration Solutions 0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000ppm, mol/L, mg/L
   mV Range -1999.9~1999.9mV
   mV Accuracy ±0.2mV
   Resolution 0.1, 1mV, selectable
   Conductivity Range 0~20mS/cm (Max.200mS/cm)
   Conductivity Accuracy ±0.5% Full Scale
   Calibration Points Up to 5 points
   Calibration Solutions 10uS/cm, 84uS/cm, 1413uS/cm, 12.88mS/cm, 111.8mS/cm
   TDS Range 0~10ppt (Max. 20ppt, Depending on factor setting)
   TDS Accuracy ±1% Full Scale
   TDS Factor 0.1~1.0 (Default 0.5)
   Salinity Range 0~10ppt (Max.80ppt)
   Salinity Accuracy ±1% Full Scale
   Salinity Measurement Modes Practical Salinity (PSU) or Seawater Measurement Standard (ppt)
   Resistivity Range 0~100MΩ
   Resistivity Accuracy ±1% Full Scale
   Resolution 0.001, 0.01, 0.1, 1, Automatic
   Temperature Coefficient 0.0~10.0% per °C
   Compensation Modes Linear or Pure Water
   Cell Constant K=0.1, 1, 10, selectable
   Normalization Temperature 20°C or 25°C
   Dissolved Oxygen Range 0.00~20.00mg/L or ppm
   Resolution 0.01, 0.1mg/L, selectable
   Dissolved Oxygen Accuracy ±0.2mg/L (Calibration and measurement under the conditions of same temperature)
   % Saturation of Oxygen 0.0~200.0%
   Accuracy ±2.0%
   Salinity Correction 0~50g/L
   Pressure Correction 60.0~112.5kPa, 450~850mmHg
   Temperature Range 0~105°C, 32~221°F
   Temperature Accuracy ±0.5°C, ±0.9°F
   Temperature Calibration Manual
   Temperature Compensation 0~100°C, 32~212°F, Automatic or Manual; DO Mode: 0~50°C, 32~122°F, Automatic
   Auto-Off Manual or Automatic (10, 20, 30 minutes after last key pressed, selectable)
   Hold Function Manual or Automatic
   Stability Conditions Low or High, selectable
   Calibration due reminder 0 to 30 days
   Reset Function Yes
   Memory 500 data sets with Date/Time stamping
   Output USB Communication Interface
   Connector BNC and 6-pin connector
   Power Requirements 3×1.5V “AA” Batteries
   LCD Display Custom dual-display LCD (130×110mm)
   Dimensions 170(L)×85(W)×30(H)mm
   Weight 300 grams

 

Brosur 577 PH900P Portable Multi-parameter Water Quality Meter

Detail Produk

Kategori : LAIN-LAIN
Model PH900P
   pH Range -2.000~20.000pH
   pH Accuracy ±0.002pH
   Resolution 0.001, 0.01, 0.1pH, selectable
   Calibration Points Up to 5 points
   Calibration Solutions USA(pH1.68/4.01/7.00/10.01/12.45), NIST(pH1.68/4.01/6.86/9.18/12.45), DIN(pH1.09/4.65/6.79/9.23/12.75)
   Ion Concentration Range 0.001~19999ppm, mg/L, mol/L (Depending on measuring range of Ion selective Electrode)
   Ion Concentration Accuracy ±0.5% Full Scale (Monovalent), ±1% Full Scale (Divalent)
   Calibration Points 2 to 5 points
   Calibration Solutions 0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000ppm, mol/L, mg/L
   mV Range -1999.9~1999.9mV
   mV Accuracy ±0.2mV
   Resolution 0.1, 1mV, selectable
   Conductivity Range 0~20mS/cm (Max.200mS/cm)
   Conductivity Accuracy ±0.5% Full Scale
   Calibration Points Up to 5 points
   Calibration Solutions 10uS/cm, 84uS/cm, 1413uS/cm, 12.88mS/cm, 111.8mS/cm
   TDS Range 0~10ppt (Max. 20ppt, Depending on factor setting)
   TDS Accuracy ±1% Full Scale
   TDS Factor 0.1~1.0 (Default 0.5)
   Salinity Range 0~10ppt (Max.80ppt)
   Salinity Accuracy ±1% Full Scale
   Salinity Measurement Modes Practical Salinity (PSU) or Seawater Measurement Standard (ppt)
   Resistivity Range 0~100MΩ
   Resistivity Accuracy ±1% Full Scale
   Resolution 0.001, 0.01, 0.1, 1, Automatic
   Temperature Coefficient 0.0~10.0% per °C
   Compensation Modes Linear or Pure Water
   Cell Constant K=0.1, 1, 10, selectable
   Normalization Temperature 20°C or 25°C
   Dissolved Oxygen Range 0.00~20.00mg/L or ppm
   Resolution 0.01, 0.1mg/L, selectable
   Dissolved Oxygen Accuracy ±0.2mg/L (Calibration and measurement under the conditions of same temperature)
   % Saturation of Oxygen 0.0~200.0%
   Accuracy ±2.0%
   Salinity Correction 0~50g/L
   Pressure Correction 60.0~112.5kPa, 450~850mmHg
   Temperature Range 0~105°C, 32~221°F
   Temperature Accuracy ±0.5°C, ±0.9°F
   Temperature Calibration Manual
   Temperature Compensation 0~100°C, 32~212°F, Automatic or Manual; DO Mode: 0~50°C, 32~122°F, Automatic
   Auto-Off Manual or Automatic (10, 20, 30 minutes after last key pressed, selectable)
   Hold Function Manual or Automatic
   Stability Conditions Low or High, selectable
   Calibration due reminder 0 to 30 days
   Reset Function Yes
   Memory 500 data sets with Date/Time stamping
   Output USB Communication Interface
   Connector BNC and 6-pin connector
   Power Requirements 3×1.5V “AA” Batteries
   LCD Display Custom dual-display LCD (130×110mm)
   Dimensions 170(L)×85(W)×30(H)mm
   Weight 300 grams

 

Brosur 577 PH900P Portable Multi-parameter Water Quality Meter