The Hitachi UH5300 is an innovative, double-beam UV-Visible system. It incorporates the latest IT technology and can be operated in…
sold out
Rp

The Hitachi UH5300 is an innovative, double-beam UV-Visible system. It incorporates the latest IT technology and can be operated in a wireless configuration from an iPad® or PC, or wired directly to a PC. When connected to a Wi-Fi router, you can control the instrument, print reports, and export data wirelessly from an iPad or PC, providing a new way to work in your laboratory

The UH5300 is designed with the environment in mind by using a long-life pulsed Xe lamp with a 7-year warranty(*), offering reliability and low operational cost. With the standard 6-position automatic cell changer and intelligent sample compartment door, this instrument affords a high-throughput sample measurement. Simple and easy performance check functions assure the accuracy of measured data.

*:
A 7-year warranty requires compliance with instrument registration.

VIDIO

Configuration Examples

Wireless configuration with a Wi-Fi router and an iPad

Wired configuration with a PC and printer

Hitachi UV-Vis spectrophotometer can be controlled with an iPad

Note: iPad is a registered trademark of Apple Inc.
UH5300 UV-VIS double-Beam Routine Spectrophotometer Specifications
Wavelength range 190 to 1,100 nm
Band pass 1 nm
Scan speed 10, 40, 100, 200, 400, 800, 1200, 2400, 4800, 6000 nm/min
Wavelength accuracy ±0.3 nm (Xe: 260.6, 484.3, 881.9 nm; Hg: 253.7, 435.8, 546.1 nm)
Baseline stability 0.0005 Abs/h (260 nm, 2 hrs. after power-on)
Noise level 0.0001 Abs or less (RMS, 260 nm, 0 Abs)
Baseline flatness ±0.0009 Abs (200 to 950 nm)
Light source Xenon (Xe) flash lamp
Detector Silicon photodiode
Photometric range Abs: -3.3 to 3.3 Abs
0 to 300%T
Photometric accuracy ±0.002 Abs (0 to 0.5 Abs)
±0.004 Abs (0.5 to 1.0 Abs)
(certified for NIST SRM 930)
Dimensions 510 mm (W) x 490 mm (D) x 280 mm (H)
Weight Approx. 19 kg
Power requirements 100, 115, 220, 230 or 240 V, 50/60 Hz, 150 VA
POWER CONSUMPTION 70 W or less
Double Beam Spectrophotometer UH5300 HITACHI
PC Dell & Printer EPSON Warna
Minimum Processor Intel Core i5, RAM 4GB RAM HDD 500 GB, Mouse + Keyboard, Monitor LED 20″ + OS Windows 7 Pro 64bit, Printer Laser Jet + Win 7 Pro 64bit
Optical system Czerny-Turner mount, Double beam monochromator
Wavelength range 190 to 1,100 nm
Spectral band width 1 nm
Stray light 198 nm (KCI) : 1.0 % or less     220 nm (Nal) : 0.05 % or less
340 nm (NaNO2) : 0.05 % or less
Wavelength accuracy ±0.3 nm (Xe : 260.6, 484.3, 881.9 nm, Hg : 253.7, 435.8, 546.1 nm)
Wavelength repeatability ±0.1 nm
Photometric range Abs : -3.3 to 3.3   %T : 0 to 300
Photometric accuracy ±0.002 Abs (0 to 0.5 Abs)
(certified according to NIST SRM 930) ±0.004 Abs (0.5 to 1.0 Abs)
Photometric repeatability ±0.002 Abs (0 to 1.0 Abs)
(repeatability according to NIST SRM 930)
Scan speed 10, 40, 100, 200, 400, 800, 1,200, 2,400, 4,800, 6,000 nm/min
Response Fast, Medium, Slow
Baseline stability 0.0005 Abs/h (260 nm after a two-hour warm-up period)
Noise level 0.0001 Abs (RMS, 260 nm, 0 Abs)
Baseline flatness ±0.0009 Abs (200 to 950 nm)
Light source Xenon flash lamp
Detector Silicon photodiode
Cell holder Automatic 6-cell turret    *Single cell holder are available as an option.
Printer output For connection to iPad : AirPrint-compatible printer
For connection to PC : PC-compatible printer
Interface LAN port : connected to a router or PC
USB port : connected to USB memory for use when transferring CSV-
format files
Size (main Unit) 510 (W) × 490 (D) × 280 (H) mm
Weight 19 kg
Power 100, 115, 220, 230, 240V, 50/60 Hz, 150VA
Power consumption 70 W or Less
Ambient temperature 15 to 35 ˚C
Ambient humidity 25 to 80 % (no condensation, to be 70 % or less at temperatures
exceeding 30 ˚C)
Include:
RECTANGULAR QUARTZ CELL, 10MM, 2 pcs/set
IPAD to Oprational
Installation dan Pelatihan Penggunaan alat kepada user sampai bisa
Kalibrasi ulang selama 2 kali dan Fasilitasi kalibrasi berkelanjutan
Kunjungan Teknisi Rutin Secara Berkala Setiap 3 Bulan sekali untuk perawatan alat
Jaminan Ketersediaan Sparepart Selama alat di gunakan
Include Warranty 30 months
Printer EPSON Warna

BROCHURE

2. UH5300Brochure-HTB-E094

Detail Produk

Kategori : ALAT LABORATORIUM

The Hitachi UH5300 is an innovative, double-beam UV-Visible system. It incorporates the latest IT technology and can be operated in a wireless configuration from an iPad® or PC, or wired directly to a PC. When connected to a Wi-Fi router, you can control the instrument, print reports, and export data wirelessly from an iPad or PC, providing a new way to work in your laboratory

The UH5300 is designed with the environment in mind by using a long-life pulsed Xe lamp with a 7-year warranty(*), offering reliability and low operational cost. With the standard 6-position automatic cell changer and intelligent sample compartment door, this instrument affords a high-throughput sample measurement. Simple and easy performance check functions assure the accuracy of measured data.

*:
A 7-year warranty requires compliance with instrument registration.

VIDIO

Configuration Examples

Wireless configuration with a Wi-Fi router and an iPad

Wired configuration with a PC and printer

Hitachi UV-Vis spectrophotometer can be controlled with an iPad

Note: iPad is a registered trademark of Apple Inc.
UH5300 UV-VIS double-Beam Routine Spectrophotometer Specifications
Wavelength range 190 to 1,100 nm
Band pass 1 nm
Scan speed 10, 40, 100, 200, 400, 800, 1200, 2400, 4800, 6000 nm/min
Wavelength accuracy ±0.3 nm (Xe: 260.6, 484.3, 881.9 nm; Hg: 253.7, 435.8, 546.1 nm)
Baseline stability 0.0005 Abs/h (260 nm, 2 hrs. after power-on)
Noise level 0.0001 Abs or less (RMS, 260 nm, 0 Abs)
Baseline flatness ±0.0009 Abs (200 to 950 nm)
Light source Xenon (Xe) flash lamp
Detector Silicon photodiode
Photometric range Abs: -3.3 to 3.3 Abs
0 to 300%T
Photometric accuracy ±0.002 Abs (0 to 0.5 Abs)
±0.004 Abs (0.5 to 1.0 Abs)
(certified for NIST SRM 930)
Dimensions 510 mm (W) x 490 mm (D) x 280 mm (H)
Weight Approx. 19 kg
Power requirements 100, 115, 220, 230 or 240 V, 50/60 Hz, 150 VA
POWER CONSUMPTION 70 W or less
Double Beam Spectrophotometer UH5300 HITACHI
PC Dell & Printer EPSON Warna
Minimum Processor Intel Core i5, RAM 4GB RAM HDD 500 GB, Mouse + Keyboard, Monitor LED 20″ + OS Windows 7 Pro 64bit, Printer Laser Jet + Win 7 Pro 64bit
Optical system Czerny-Turner mount, Double beam monochromator
Wavelength range 190 to 1,100 nm
Spectral band width 1 nm
Stray light 198 nm (KCI) : 1.0 % or less     220 nm (Nal) : 0.05 % or less
340 nm (NaNO2) : 0.05 % or less
Wavelength accuracy ±0.3 nm (Xe : 260.6, 484.3, 881.9 nm, Hg : 253.7, 435.8, 546.1 nm)
Wavelength repeatability ±0.1 nm
Photometric range Abs : -3.3 to 3.3   %T : 0 to 300
Photometric accuracy ±0.002 Abs (0 to 0.5 Abs)
(certified according to NIST SRM 930) ±0.004 Abs (0.5 to 1.0 Abs)
Photometric repeatability ±0.002 Abs (0 to 1.0 Abs)
(repeatability according to NIST SRM 930)
Scan speed 10, 40, 100, 200, 400, 800, 1,200, 2,400, 4,800, 6,000 nm/min
Response Fast, Medium, Slow
Baseline stability 0.0005 Abs/h (260 nm after a two-hour warm-up period)
Noise level 0.0001 Abs (RMS, 260 nm, 0 Abs)
Baseline flatness ±0.0009 Abs (200 to 950 nm)
Light source Xenon flash lamp
Detector Silicon photodiode
Cell holder Automatic 6-cell turret    *Single cell holder are available as an option.
Printer output For connection to iPad : AirPrint-compatible printer
For connection to PC : PC-compatible printer
Interface LAN port : connected to a router or PC
USB port : connected to USB memory for use when transferring CSV-
format files
Size (main Unit) 510 (W) × 490 (D) × 280 (H) mm
Weight 19 kg
Power 100, 115, 220, 230, 240V, 50/60 Hz, 150VA
Power consumption 70 W or Less
Ambient temperature 15 to 35 ˚C
Ambient humidity 25 to 80 % (no condensation, to be 70 % or less at temperatures
exceeding 30 ˚C)
Include:
RECTANGULAR QUARTZ CELL, 10MM, 2 pcs/set
IPAD to Oprational
Installation dan Pelatihan Penggunaan alat kepada user sampai bisa
Kalibrasi ulang selama 2 kali dan Fasilitasi kalibrasi berkelanjutan
Kunjungan Teknisi Rutin Secara Berkala Setiap 3 Bulan sekali untuk perawatan alat
Jaminan Ketersediaan Sparepart Selama alat di gunakan
Include Warranty 30 months
Printer EPSON Warna

BROCHURE

2. UH5300Brochure-HTB-E094