Specification: Item content Output power 65kW Main inverter frequency 60kHz X-ray tube (Toshiba E7252X) Rotary anode, dual-focus Large/ Small focus 1.2mm/…
stock ready
Rp

Specification:

Item content
Output power 65kW
Main inverter frequency 60kHz
X-ray tube

(Toshiba E7252X)

Rotary anode, dual-focus
Large/ Small focus 1.2mm/ 0.6mm
Power of large/ small focus 75kW/ 27kW.
Anode thermal capacity 210kJ
Tube thermal capacity 900kJ
Rotary anode speed 9700rpm
Anode target surface angle 12°
mA range 10mA-650mA
Tube voltage 40kV-150kV
Exposure Time 0.001s-12.5s
mAs 0.1-630mAs
Table radiography grids Grid density: 103L/inch

Grid ratio: 10:1;

Focusing Distance: 120cm

Stationary type: 18″×18″

Cassette Film size: 356*432mm(14”*17*)

Longitudinal movement: 560mm

Mechanical Movement SID: 450-1200mm
X-ray tube Longitudinal movement 1370mm
X-ray tube Rotation range around transverse axis ±90°
X-ray tube Rotation range around X-ray tube axis 35°
X-ray tube Rotation range around pillar 4* 90°
Table Table size 2000×760mm
Table height ≤700mm
Table transverse movement ≥220mm
Table longitudinal movement ≥900mm
Power supply 380/400VAC three phase

50Hz

Operation method 1. Close-table graphic program controlled LCD touchable screen operation

2. Wireless remote control exposure

Detail Produk

Kategori : LAIN-LAIN

Specification:

Item content
Output power 65kW
Main inverter frequency 60kHz
X-ray tube

(Toshiba E7252X)

Rotary anode, dual-focus
Large/ Small focus 1.2mm/ 0.6mm
Power of large/ small focus 75kW/ 27kW.
Anode thermal capacity 210kJ
Tube thermal capacity 900kJ
Rotary anode speed 9700rpm
Anode target surface angle 12°
mA range 10mA-650mA
Tube voltage 40kV-150kV
Exposure Time 0.001s-12.5s
mAs 0.1-630mAs
Table radiography grids Grid density: 103L/inch

Grid ratio: 10:1;

Focusing Distance: 120cm

Stationary type: 18″×18″

Cassette Film size: 356*432mm(14”*17*)

Longitudinal movement: 560mm

Mechanical Movement SID: 450-1200mm
X-ray tube Longitudinal movement 1370mm
X-ray tube Rotation range around transverse axis ±90°
X-ray tube Rotation range around X-ray tube axis 35°
X-ray tube Rotation range around pillar 4* 90°
Table Table size 2000×760mm
Table height ≤700mm
Table transverse movement ≥220mm
Table longitudinal movement ≥900mm
Power supply 380/400VAC three phase

50Hz