Alpha-1106 Visible Spectrophotometer
Alpha-1106 Visible SpectrophotometerAlpha-1106 Visible Spectrophotometer

Alpha-1106 Visible Spectrophotometer

5 (1 votes)

share

The Model Alpha-1106 is a single beam, general purpose instrument designed to meet the needs of the Conventional Laboratory, It…
sold out
Rp

The Model Alpha-1106 is a single beam, general purpose instrument designed to meet the needs of the Conventional Laboratory, It is ideal for various applications, such as: Clinical Chemistry, Biochemistry, Petro chemistry, Environmental Protection, Food and Beverage Labs, Water and Waste Water Labs and other fields of quality control and research.

The Model Alpha-1106 features a digital display of photometric result, easy operation and wavelength range of 325-1100nm. This instrument is ideal for measurements in the visible wavelength region of the electromagnetic spectrum.

The spectrophotometer consists of five parts:

Halogen lamp to supply the light
A Monochromator to isolate the wavelength of interest and eliminate the unwanted second order radiation
A sample compartment to accommodate the sample solution
A detector to receive the transmitted light and convert it to an electrical signal
A digital display to indicate absorbance or transmittance. The block diagram below illustrates the relationship between these parts.
In your spectrophotometer, light from the lamp is focused on the entrance slit of the monochromator where the collimating mirror directs the beam onto the grating. The grating disperses the light beam to produce the spectrum, a portion of which is focused on the exit slit of the monochromator by a collimating mirror. From here the beam is passed to a sample compartment through one of the filters, which helps to eliminate unwanted second order radiation from the diffraction grating. Upon leaving the sample compartment, the beam is passed to the silicon photodiode detector and causes the detector to produce an electrical signal that is displayed on the digital display.

The Alpha-1106 incorporates an USB1.0 for connecting to a PC via the Application Software, also design a RS232 port for built-in thermal printer.

Wavelength Range 325-1100nm
Spectral Band pass 2nm/4nm (Optional)
Optical System Single beam, Littrow,Grating 1200 Line/mm
Wavelength Accuracy ±0.8nm
Wavelength Repeatability ±0.3nm
Wavelength Resolution 0.1nm
Photometric Range 0-200%T,-0.3-3A,-9999-9999C
Photometric Accuracy
±0.002A(0~0.5A), ±0.004A(0.5~1A)
±0.008A(1~2A), ±0.3%T(0~100%T)

Photometric Repeatability ±0.001A(0~0.5A), ±0.002A(0.5~1A)
±0.004A(1~2A), ±0.15%T(0~100%T)
Stray Light ≤0.05%T@340nm
Stability ±0.002A/hr @500nm,0A
Data Output 128X64 Dots Array Graphic LCD,
Built-in Printer(Optional),
USB1.1 Connecting to computer
Size(mm) 570×460×230
Weight 13.5kg

 

Brosur

39. Laxco Operational Manual for Alpha-1106 1506

Detail Produk

Kategori : LAIN-LAIN

The Model Alpha-1106 is a single beam, general purpose instrument designed to meet the needs of the Conventional Laboratory, It is ideal for various applications, such as: Clinical Chemistry, Biochemistry, Petro chemistry, Environmental Protection, Food and Beverage Labs, Water and Waste Water Labs and other fields of quality control and research.

The Model Alpha-1106 features a digital display of photometric result, easy operation and wavelength range of 325-1100nm. This instrument is ideal for measurements in the visible wavelength region of the electromagnetic spectrum.

The spectrophotometer consists of five parts:

Halogen lamp to supply the light
A Monochromator to isolate the wavelength of interest and eliminate the unwanted second order radiation
A sample compartment to accommodate the sample solution
A detector to receive the transmitted light and convert it to an electrical signal
A digital display to indicate absorbance or transmittance. The block diagram below illustrates the relationship between these parts.
In your spectrophotometer, light from the lamp is focused on the entrance slit of the monochromator where the collimating mirror directs the beam onto the grating. The grating disperses the light beam to produce the spectrum, a portion of which is focused on the exit slit of the monochromator by a collimating mirror. From here the beam is passed to a sample compartment through one of the filters, which helps to eliminate unwanted second order radiation from the diffraction grating. Upon leaving the sample compartment, the beam is passed to the silicon photodiode detector and causes the detector to produce an electrical signal that is displayed on the digital display.

The Alpha-1106 incorporates an USB1.0 for connecting to a PC via the Application Software, also design a RS232 port for built-in thermal printer.

Wavelength Range 325-1100nm
Spectral Band pass 2nm/4nm (Optional)
Optical System Single beam, Littrow,Grating 1200 Line/mm
Wavelength Accuracy ±0.8nm
Wavelength Repeatability ±0.3nm
Wavelength Resolution 0.1nm
Photometric Range 0-200%T,-0.3-3A,-9999-9999C
Photometric Accuracy
±0.002A(0~0.5A), ±0.004A(0.5~1A)
±0.008A(1~2A), ±0.3%T(0~100%T)

Photometric Repeatability ±0.001A(0~0.5A), ±0.002A(0.5~1A)
±0.004A(1~2A), ±0.15%T(0~100%T)
Stray Light ≤0.05%T@340nm
Stability ±0.002A/hr @500nm,0A
Data Output 128X64 Dots Array Graphic LCD,
Built-in Printer(Optional),
USB1.1 Connecting to computer
Size(mm) 570×460×230
Weight 13.5kg

 

Brosur

39. Laxco Operational Manual for Alpha-1106 1506