Ammonia, Low Range, Portable Photometer
Ammonia, Low Range, Portable Photometer

Ammonia, Low Range, Portable Photometer

5 (1 votes)

share

Ammonia, Low Range, Portable Photometer Hanna Instruments HI 96700 Description: CAL CHECK™ User calibration Certified calibration and verification standards BEPS…
sold out
Rp
Ammonia, Low Range, Portable Photometer
Hanna Instruments HI 96700
Description:
  • CAL CHECK™
  • User calibration
  • Certified calibration and verification standards
  • BEPS (Battery Error Prevention System)
  • TIMER function
  • Auto shut-off
  • GLP Features
The HI 96700 meter measures the ammonia-nitrogen (NH3-N) content in water samples.
These meters use an exclusive positive-locking system to ensure that the cuvette is in the
same place every time it is placed into the measurement cell.
Ammonia is often an excellent indication of the presence of animal or plant microbiological
decay. It is tested in fish farms (fresh and salt water tanks) due to the damaging effects of
its toxic nature. Its presence in rivers and reservoirs normally points to agricultural and/or
civil pollutants. Ammonia is tested in lakes, rivers, portable water, boiler feed water, sewage,
industrial and waste water.
Specifications:
Range
 
0.00 to 3.00 mg/L (ppm)
Resolution
 
0.01 mg/L (ppm)
Accuracy
 
±0.04 mg/L (ppm) ±4% of reading @ 25°C
Light Source
 
Tungsten lamp
Light Detector
 
silicon photocell with narrow band interference filter @ 420 nm
Environment
 
0 to 50°C (32 to 122°F); RH max 95% non-condensing
Power Supply
 
9V battery
Auto-off
 
After 10 minutes of non-use in measuring mode After 1 hour of non-use in
calibration mode with last reading reminder
Dimensions
 
192 x 104 x 69 mm (7.6 x 4.1 x 2.7″)
Weight
 
360 g (12.7 oz.)
Method
 
Adaptation of the ASTM Manual of Water and Environmental Technology,
D1426-92, Nessler method.

Detail Produk

Kategori : LAIN-LAIN
Ammonia, Low Range, Portable Photometer
Hanna Instruments HI 96700
Description:
  • CAL CHECK™
  • User calibration
  • Certified calibration and verification standards
  • BEPS (Battery Error Prevention System)
  • TIMER function
  • Auto shut-off
  • GLP Features
The HI 96700 meter measures the ammonia-nitrogen (NH3-N) content in water samples.
These meters use an exclusive positive-locking system to ensure that the cuvette is in the
same place every time it is placed into the measurement cell.
Ammonia is often an excellent indication of the presence of animal or plant microbiological
decay. It is tested in fish farms (fresh and salt water tanks) due to the damaging effects of
its toxic nature. Its presence in rivers and reservoirs normally points to agricultural and/or
civil pollutants. Ammonia is tested in lakes, rivers, portable water, boiler feed water, sewage,
industrial and waste water.
Specifications:
Range
 
0.00 to 3.00 mg/L (ppm)
Resolution
 
0.01 mg/L (ppm)
Accuracy
 
±0.04 mg/L (ppm) ±4% of reading @ 25°C
Light Source
 
Tungsten lamp
Light Detector
 
silicon photocell with narrow band interference filter @ 420 nm
Environment
 
0 to 50°C (32 to 122°F); RH max 95% non-condensing
Power Supply
 
9V battery
Auto-off
 
After 10 minutes of non-use in measuring mode After 1 hour of non-use in
calibration mode with last reading reminder
Dimensions
 
192 x 104 x 69 mm (7.6 x 4.1 x 2.7″)
Weight
 
360 g (12.7 oz.)
Method
 
Adaptation of the ASTM Manual of Water and Environmental Technology,
D1426-92, Nessler method.