Audiometer sibelsound 400-AO	Sibelmed
Audiometer sibelsound 400-AO	Sibelmed

Audiometer sibelsound 400-AO Sibelmed

5 (1 votes)

share

Main features : • Advanced digital technology based on DSP • Calculation of hearing loss and diagnosis • Internal database…
sold out
Rp

Main features :
• Advanced digital technology based on DSP
• Calculation of hearing loss and diagnosis
• Internal database > 1000 tests
• Suprathreshold tests
• High frequency
• Musical frequencies
• Automatic masking
• Connectivity with other management systems (EMR – Electronic Medical Record)
• Customizable settings *see configurations”

TECHNICAL SPECIFICATIONS

Standard Frequency
125
250
500
750
1000
1500
2000
3000
4000
6000
8000
Hz
Musical Frequency
131
262
523
1047
2093
4186
8372
Hz
Air Conduction
80
100
120
120
120
120
120
120
120
110
110
dB HL
Bone Conduction
50
60
60
70
70
70
70
70
dB HL
Free Field
70
80
80
80
80
80
80
80
80
dB HL
Masking Noise
Narrow Bandwidth AC
60
80
100
100
100
100
100
100
100
100
90
dB HL
Narrow Bandwidth BC
50
60
60
70
70
70
70
70
dB HL
White AC
100
dB SPL
Speech
100
dB SPL
Logo-Audiometry
Air Conduction
90
90
90
90
50
50
50
50
50
dB HL
Minimum Levels
All Options
-10
-10
-10
-10
-10
-10
-10
-10
-10
-10
-10
dB HL
High Frequency
-20
-20
-20
-20
-20
-20
-20
-20
-20
-20
-20
dB HL
Level Increases
Standard
5
5
5
5
5
5
5
5
5
5
5
dB
Reference Tone
1
1
1
1
1
1
1
1
1
1
1
dB
Frequency Precision
± 1%
Level Precision
± 2%
dB SPL

Channels: Two
Functional specifications: See tables of models and frequencies
Transducers: TDH39 – HDA200 – B71 (depending on the model)
Screen: LCD alphanumeric backlighted 2 X 16
Protection: Time restricted high frequency signals to protect both patient and unit
Self-check: Automatically checks the status of the audiometer
Unit test: Allows the user or technician to check the condition of certain functions or components
Custom settings: Programme to personalise the audiometer according to the needs of the user
Calibrations: Equipped with calibrations according to ISO and ANSI
Safety standards: EN60601-1, EN60601-1-1, EN60601-1-2, EN60601-1-4
Audiometry standards: IEC60645-1, IEC60645-2, IEC60645-4
Calibration standards: EN ISO 389-1, EN ISO 389-3, EN ISO 389-4, EN ISO 389-5, EN ISO 389-7, ANSI S3.6-2004
Working temperature: 10 to 40 ºC
Relative humidity: <90% (no condensation)
Power supply: 100 to 240V ±10% / 50/60 Hz ±3%
Power: <50 VA
Dimensions: 390 mm x 260 mm x 105 mm
Weight: 2.4 kg without accessories
Standard accessories: Depending on the model
Optional accessories: Depending on the model

Detail Produk

Kategori : LAIN-LAIN

Main features :
• Advanced digital technology based on DSP
• Calculation of hearing loss and diagnosis
• Internal database > 1000 tests
• Suprathreshold tests
• High frequency
• Musical frequencies
• Automatic masking
• Connectivity with other management systems (EMR – Electronic Medical Record)
• Customizable settings *see configurations”

TECHNICAL SPECIFICATIONS

Standard Frequency
125
250
500
750
1000
1500
2000
3000
4000
6000
8000
Hz
Musical Frequency
131
262
523
1047
2093
4186
8372
Hz
Air Conduction
80
100
120
120
120
120
120
120
120
110
110
dB HL
Bone Conduction
50
60
60
70
70
70
70
70
dB HL
Free Field
70
80
80
80
80
80
80
80
80
dB HL
Masking Noise
Narrow Bandwidth AC
60
80
100
100
100
100
100
100
100
100
90
dB HL
Narrow Bandwidth BC
50
60
60
70
70
70
70
70
dB HL
White AC
100
dB SPL
Speech
100
dB SPL
Logo-Audiometry
Air Conduction
90
90
90
90
50
50
50
50
50
dB HL
Minimum Levels
All Options
-10
-10
-10
-10
-10
-10
-10
-10
-10
-10
-10
dB HL
High Frequency
-20
-20
-20
-20
-20
-20
-20
-20
-20
-20
-20
dB HL
Level Increases
Standard
5
5
5
5
5
5
5
5
5
5
5
dB
Reference Tone
1
1
1
1
1
1
1
1
1
1
1
dB
Frequency Precision
± 1%
Level Precision
± 2%
dB SPL

Channels: Two
Functional specifications: See tables of models and frequencies
Transducers: TDH39 – HDA200 – B71 (depending on the model)
Screen: LCD alphanumeric backlighted 2 X 16
Protection: Time restricted high frequency signals to protect both patient and unit
Self-check: Automatically checks the status of the audiometer
Unit test: Allows the user or technician to check the condition of certain functions or components
Custom settings: Programme to personalise the audiometer according to the needs of the user
Calibrations: Equipped with calibrations according to ISO and ANSI
Safety standards: EN60601-1, EN60601-1-1, EN60601-1-2, EN60601-1-4
Audiometry standards: IEC60645-1, IEC60645-2, IEC60645-4
Calibration standards: EN ISO 389-1, EN ISO 389-3, EN ISO 389-4, EN ISO 389-5, EN ISO 389-7, ANSI S3.6-2004
Working temperature: 10 to 40 ºC
Relative humidity: <90% (no condensation)
Power supply: 100 to 240V ±10% / 50/60 Hz ±3%
Power: <50 VA
Dimensions: 390 mm x 260 mm x 105 mm
Weight: 2.4 kg without accessories
Standard accessories: Depending on the model
Optional accessories: Depending on the model