Main features :
• Advanced digital technology based on DSP
• Calculation of hearing loss and diagnosis
• Internal database > 1000 tests
• Suprathreshold tests
• High frequency
• Musical frequencies
• Automatic masking
• Connectivity with other management systems (EMR – Electronic Medical Record)
• Customizable settings *see configurations”
TECHNICAL SPECIFICATIONS
Standard Frequency
|
125
|
250
|
500
|
750
|
1000
|
1500
|
2000
|
3000
|
4000
|
6000
|
8000
|
Hz
|
Musical Frequency
|
131
|
262
|
523
|
–
|
1047
|
–
|
2093
|
–
|
4186
|
–
|
8372
|
Hz
|
Air Conduction
|
80
|
100
|
120
|
120
|
120
|
120
|
120
|
120
|
120
|
110
|
110
|
dB HL
|
Bone Conduction
|
–
|
50
|
60
|
60
|
70
|
70
|
70
|
70
|
70
|
–
|
–
|
dB HL
|
Free Field
|
–
|
70
|
80
|
80
|
80
|
80
|
80
|
80
|
80
|
80
|
–
|
dB HL
|
Masking Noise
|
||||||||||||
Narrow Bandwidth AC
|
60
|
80
|
100
|
100
|
100
|
100
|
100
|
100
|
100
|
100
|
90
|
dB HL
|
Narrow Bandwidth BC
|
–
|
50
|
60
|
60
|
70
|
70
|
70
|
70
|
70
|
–
|
–
|
dB HL
|
White AC
|
100
|
dB SPL
|
||||||||||
Speech
|
100
|
dB SPL
|
||||||||||
Logo-Audiometry
|
||||||||||||
Air Conduction
|
90
|
90
|
90
|
90
|
50
|
50
|
50
|
50
|
50
|
–
|
–
|
dB HL
|
Minimum Levels
|
||||||||||||
All Options
|
-10
|
-10
|
-10
|
-10
|
-10
|
-10
|
-10
|
-10
|
-10
|
-10
|
-10
|
dB HL
|
High Frequency
|
-20
|
-20
|
-20
|
-20
|
-20
|
-20
|
-20
|
-20
|
-20
|
-20
|
-20
|
dB HL
|
Level Increases
|
||||||||||||
Standard
|
5
|
5
|
5
|
5
|
5
|
5
|
5
|
5
|
5
|
5
|
5
|
dB
|
Reference Tone
|
1
|
1
|
1
|
1
|
1
|
1
|
1
|
1
|
1
|
1
|
1
|
dB
|
Frequency Precision
|
± 1%
|
|||||||||||
Level Precision
|
± 2%
|
dB SPL
|
Channels: Two
Functional specifications: See tables of models and frequencies
Transducers: TDH39 – HDA200 – B71 (depending on the model)
Screen: LCD alphanumeric backlighted 2 X 16
Protection: Time restricted high frequency signals to protect both patient and unit
Self-check: Automatically checks the status of the audiometer
Unit test: Allows the user or technician to check the condition of certain functions or components
Custom settings: Programme to personalise the audiometer according to the needs of the user
Calibrations: Equipped with calibrations according to ISO and ANSI
Safety standards: EN60601-1, EN60601-1-1, EN60601-1-2, EN60601-1-4
Audiometry standards: IEC60645-1, IEC60645-2, IEC60645-4
Calibration standards: EN ISO 389-1, EN ISO 389-3, EN ISO 389-4, EN ISO 389-5, EN ISO 389-7, ANSI S3.6-2004
Working temperature: 10 to 40 ºC
Relative humidity: <90% (no condensation)
Power supply: 100 to 240V ±10% / 50/60 Hz ±3%
Power: <50 VA
Dimensions: 390 mm x 260 mm x 105 mm
Weight: 2.4 kg without accessories
Standard accessories: Depending on the model
Optional accessories: Depending on the model