Biobase touch screen Hematology Analyzer BK6390
Biobase touch screen Hematology Analyzer BK6390Biobase touch screen Hematology Analyzer BK6390

Biobase touch screen Hematology Analyzer BK6390

5 (1 votes)

share

①. 3 part diff of WBC. ②. 20 parameters+3 histograms. ③. 60 tests per hour.④.touch screen Features : Features: Throughput:…
sold out
Rp

①. 3 part diff of WBC. ②. 20 parameters+3 histograms. ③. 60 tests per hour.④.touch screen

Features :

Features:

Throughput: 60T/H

8 inch touch screen

20 parameters + 3 histograms

2 reagents only

3 counting modes

100,000 sample results

Support LIS and external printer

Specifications :

Model BK-6390
Throughput 60 tests/hr
Assay Items 22 parameters, 3 parts differential of WBC
Measuring Principle Impedance for cell counting Cyanide-free method for HGB
Parameters WBC, Neu#, Lym#, Mid#, Neu%,Lym%, Mid%, RBC, HGB, HCT, MCV, MCH, MCHC,RDW-SD, RDW-CV, PLT, MPV, PDW, PCT, P-LCR
Histograms HistogrWBC, RBC, PLT histogram
Sample Volume Normal:10ul;Predileted:20ul
Calibration Manual&auto calibration
Counting Modes Venous, capilary, prediluted
Printer Built-in thermal printer,USB to external printer(optional)
Language English, Spanish, Italian, Portuguese, French etc
Data Input 8 inch touch screen, keyboard, mouse
Output RS232 port, USB port, VGA port. LIS system avaliable
Storage 100,000 results with histogram
Carry-over rate Parameter CV
WBC ≤ 2%
RBC ≤ 1%
HGB ≤ 2%
PLT ≤ 2%
Background Parameter Background
WBC ≤ 0.2×109/L
RBC ≤ 0.02×1012/L
HGB ≤ 1 g/L
HCT ≤ 0.5%
PLT ≤ 10×109/L
 

Precision

 

Parameter CV Measurement range
WBC ≤ 2.0% (4.0-15.0×109)/L
RBC ≤ 1.9% (3.5-6.0×1012)/L
HGB ≤ 1.9% (110.0-180.0g)/L
MCV ≤ 0.4% (80.0-110.0)fL
PLT ≤ 4.0% (100.0-500.0×109)/L
Linearity Parameter Measurement range CV
WBC (0-5.9×109)/L

(6.0-99.9×109)/L

(±0.3×109)/L

±5%

RBC (0-0.99×1012)/L

(1.0-9.99×1012)/L

(±0.05×1012)/L

±5%

HGB (0-99.0g)/L

(100.0-300.0g)/L

(±2.0g)/L

±2%

PLT (0-99×109)/L

100-999×109)/L

(±8.0×109)/L

±10%

Power supply AC 100/220±10%,60/50Hz
Package Size 580*470*590mm
Gross Weight 26.6kg

Biobase touch screen Hematology Analyzer BK6390

Detail Produk

Kategori : ALAT KESEHATAN

①. 3 part diff of WBC. ②. 20 parameters+3 histograms. ③. 60 tests per hour.④.touch screen

Features :

Features:

Throughput: 60T/H

8 inch touch screen

20 parameters + 3 histograms

2 reagents only

3 counting modes

100,000 sample results

Support LIS and external printer

Specifications :

Model BK-6390
Throughput 60 tests/hr
Assay Items 22 parameters, 3 parts differential of WBC
Measuring Principle Impedance for cell counting Cyanide-free method for HGB
Parameters WBC, Neu#, Lym#, Mid#, Neu%,Lym%, Mid%, RBC, HGB, HCT, MCV, MCH, MCHC,RDW-SD, RDW-CV, PLT, MPV, PDW, PCT, P-LCR
Histograms HistogrWBC, RBC, PLT histogram
Sample Volume Normal:10ul;Predileted:20ul
Calibration Manual&auto calibration
Counting Modes Venous, capilary, prediluted
Printer Built-in thermal printer,USB to external printer(optional)
Language English, Spanish, Italian, Portuguese, French etc
Data Input 8 inch touch screen, keyboard, mouse
Output RS232 port, USB port, VGA port. LIS system avaliable
Storage 100,000 results with histogram
Carry-over rate Parameter CV
WBC ≤ 2%
RBC ≤ 1%
HGB ≤ 2%
PLT ≤ 2%
Background Parameter Background
WBC ≤ 0.2×109/L
RBC ≤ 0.02×1012/L
HGB ≤ 1 g/L
HCT ≤ 0.5%
PLT ≤ 10×109/L
 

Precision

 

Parameter CV Measurement range
WBC ≤ 2.0% (4.0-15.0×109)/L
RBC ≤ 1.9% (3.5-6.0×1012)/L
HGB ≤ 1.9% (110.0-180.0g)/L
MCV ≤ 0.4% (80.0-110.0)fL
PLT ≤ 4.0% (100.0-500.0×109)/L
Linearity Parameter Measurement range CV
WBC (0-5.9×109)/L

(6.0-99.9×109)/L

(±0.3×109)/L

±5%

RBC (0-0.99×1012)/L

(1.0-9.99×1012)/L

(±0.05×1012)/L

±5%

HGB (0-99.0g)/L

(100.0-300.0g)/L

(±2.0g)/L

±2%

PLT (0-99×109)/L

100-999×109)/L

(±8.0×109)/L

±10%

Power supply AC 100/220±10%,60/50Hz
Package Size 580*470*590mm
Gross Weight 26.6kg

Biobase touch screen Hematology Analyzer BK6390

Tidak ada produk berkaitan.

Tidak ada produk popular.