Technical Specifications:   Physical Characteristics   Dimensions: 330mm x 270mm x 100mm Weight: 3.5 kg. approx. Display   LED (Cadence)…
sold out
Rp

Technical Specifications:

 

Physical Characteristics

 

  • Dimensions: 330mm x 270mm x 100mm
  • Weight: 3.5 kg. approx.

Display

 

  • LED (Cadence)
  • 5.7 inch LCD (Cadence II)

Printing

 

  • Recording Paper: 112mm, Z-Fold, thermosensitive, American/International Standard
  • Paper Advance Speed: 1,2,3/cm./min. selectable
  • Record Message: Date, time, TOCO type, paper speed, FHR type, etc.

Ultrasound

 

  • Technique: Ultrasound Pulse Doppler with correlation
  • Pulse repetition rate: 2 KHz
  • Ultrasound Frequency: 1.0MHz+10%
  • FHR range: 50bpm-240bpm
  • Resolution: 1bpm
  • Accuracy: ±2bpm

DECG

 

  • Technique: Peak – Peak detection technique
  • FHR range: 30bpm-240bpm
  • Resolution: 1bpm
  • Accuracy: ±1bpm
  • Input Impedance: >10M (Differential)
  • Input Impedance: >20M (Common Mode)

TOCO

 

  • TOCO range: 0-100 Relative (%)
  • Resolution: 1%
  • Zero mode: Auto/Manual
  • Non-linear error: ≤±10%

IUP

 

  • Pressure range: 0-100 mmHg
  • Resolution: 1%
  • Zero mode: Auto/Manual
  • Non-linear error: ±3mmHg

Auto Fetal Movement (AFM)

 

  • Technique: Pulsed Doppler ultrasound
  • Range: 0-100 (%)
  • Resolution: 1%

Marking

 

  • Manual fetal movement mark

Battery

 

  • 14.8 V rechargeable Lithium-ion battery
  • Continuous working time: 2-4 hours

Communication port

 

  • RS232

Produk Pernah Dilihat

Detail Produk

Kategori : LAIN-LAIN

Technical Specifications:

 

Physical Characteristics

 

  • Dimensions: 330mm x 270mm x 100mm
  • Weight: 3.5 kg. approx.

Display

 

  • LED (Cadence)
  • 5.7 inch LCD (Cadence II)

Printing

 

  • Recording Paper: 112mm, Z-Fold, thermosensitive, American/International Standard
  • Paper Advance Speed: 1,2,3/cm./min. selectable
  • Record Message: Date, time, TOCO type, paper speed, FHR type, etc.

Ultrasound

 

  • Technique: Ultrasound Pulse Doppler with correlation
  • Pulse repetition rate: 2 KHz
  • Ultrasound Frequency: 1.0MHz+10%
  • FHR range: 50bpm-240bpm
  • Resolution: 1bpm
  • Accuracy: ±2bpm

DECG

 

  • Technique: Peak – Peak detection technique
  • FHR range: 30bpm-240bpm
  • Resolution: 1bpm
  • Accuracy: ±1bpm
  • Input Impedance: >10M (Differential)
  • Input Impedance: >20M (Common Mode)

TOCO

 

  • TOCO range: 0-100 Relative (%)
  • Resolution: 1%
  • Zero mode: Auto/Manual
  • Non-linear error: ≤±10%

IUP

 

  • Pressure range: 0-100 mmHg
  • Resolution: 1%
  • Zero mode: Auto/Manual
  • Non-linear error: ±3mmHg

Auto Fetal Movement (AFM)

 

  • Technique: Pulsed Doppler ultrasound
  • Range: 0-100 (%)
  • Resolution: 1%

Marking

 

  • Manual fetal movement mark

Battery

 

  • 14.8 V rechargeable Lithium-ion battery
  • Continuous working time: 2-4 hours