High Pressure Gradient Mixing HPLC
![](https://www.cecilinstruments.com/Adept%20logop2tmt1.jpg)
Easy to use, Versatile Modular HPLC
Whatever your HPLC requirements, Adept HPLC will provide great value plus more.
Because the systems are modular, different detectors may be accommodated depending on analytical requirements. These detectors include variable wavelength UV/Visible, WaveQuest UV/Visible ultra-
If required, extra pumps such as semi-
A wide range of autosamplers, fraction collectors, column heater/chillers, column reactors and column switching valves may be included in an Adept HPLC system.
Each Adept system can be customised to an analytical requirement.
The use of post-
The use of biocompatible options brings a streamlined approach to denaturing DNA, semi-
Analyse catecholamines in blood plasma with an electrochemical detector, whilst simultaneously analysing anions using a conductivity detector.
Detect all organic acids in wine using the conductivity detector, whist simultaneously detecting the sugars with refractive index or electrochemical detectors.
High Pressure Mixing Gradients
Using the pulse-
This makes method development and method transfer reliable and less stressful.
Comprehensive, Versatile, Intuitive and Easy to Use PowerStream software
All this provides for easy operation. PowerStream Software also provides 21 CFR part 11 Compliance.
![](https://www.cecilinstruments.com/amino%20acids.png)
Chromatogram of some common amino acids
PowerStream – System Manager Chromatography Software
PowerStream is a chromatography management system developed by Cecil Instruments. Comprehensive data processing and full control of Cecil HPLC modules is provided. PowerStream complies with the terms of 21 CFR part 11.
PowerStream, developed to operate in Windows facilitates organisation of chromatography results and methods and provides digital control for a wide range of peripherals.
Operation is remarkably easy and help screens provide a complete operating guide.
![](https://www.cecilinstruments.com/PowerStream%20logop2tm.jpg)
PowerStream is easy to use, with a fully interactive graphical interface and display providing full method development with customised parameters, data capture and manipulation of data and chromatograms. A tutorial is included for clarity and rapid learning.
Complete Flexibility
The complete range of chromatographic applications may be undertaken. Pumps may be fully programmed for any required gradient and the gradient profile may be overlayed on stored chromatograms for accurate mixture or flow adjustments. Mid elution wavelength control of the programmable UV detector is provided. Calibration curves, using any number of standards, may be computed and plotted for each component of interest and may subsequently be used to determine the concentration of unknown samples.
Comprehensive integration parameters are provided for accurate peak area and height calculations. Retention times for all peaks are tabulated.
Convenient Operation
The clarity of screen presentation is illustrated by the composite display shown for a typical gradient elution.
Clear Screen Presentation
Method creation is simple and convenient. Firstly select all the hardware to be used for the experiment and add any of the following parameters as required: Timed events, Integration parameters, Calibration curves and Reporting parameters.
Method Operation
![](https://www.cecilinstruments.com/wpimages/wpf16cd90b_06.png)
PowerStream Interface, CE 4900
PowerStream is the powerful new chromatography software, developed by Cecil Instruments R & D, for HPLC system control and data processing. It is used in conjunction with DataStream software, also developed by Cecil Instruments, to provide data transfer and comprehensive display, processing and manipulation of spectral scans.
The PowerStream system manager interface unit, shown here, is designed as a space saving stackable module. The unit is supplied whenever
CE 4900/CE 4900D PowerStream system control and data processing are required.
When system control is not required, PowerStream CE 4901 is provided, with an interface module without the control feature.
System Requirements:-
- Personal Computer with Pentium class processor.
- Pentium 1GHz or higher.
- Microsoft Windows XP, Vista, 7, 8, 10.
- 512 MB of RAM or more.
- Hard-
disk space required: 150 MB. - CD-
ROM drive. - Monitor resolution 1024 x 768 or better.
- Microsoft Mouse or compatible pointing device.
- USB port.
HPLC Pump CE 4100
Flow Rate |
0.001 to 10mL/min in 0.001 steps |
Flow Reproducibility |
Better than 0.1% |
Maximum Pressure |
40MPa = 400 bar |
User Interface |
4 line back- |
Full range of keys for menu and parameter selection |
|
Fast number entry keys |
|
Over Pressure Cut- |
Adjustable between 3 and 40MPa |
Low Pressure Cut- |
Adjustable between 0 and 40MPa |
Material in contact with fluids |
Ceramic inserts – |
Check valves – ruby and sapphire |
|
Pulsation |
Less than ±0.5% at 2mL/min |
Size and Weight |
365 x 290 x 140mm, 7.5kg. |
Power Requirements |
115V or 230V, 50/60Hz, 30VA |
Quaternary Low Pressure Pump CE 4104
Flow Rate |
0.001 to 10mL/min in 0.001/min increments |
Pressure Range |
0- |
Flow Accuracy |
<±0.5% |
Flow Precision |
<0.1% RSD |
Pressure Pulsation |
<±0.5% at 2mL/min |
Gradient Forming |
Quaternary to Binary low pressure mixing and isocratic high pressure operation |
Gradient Control |
Using proprietary high- |
Gradient Precision |
Typically 0.2% RSD at 1mL/min |
Material in contact with fluids |
Ceramic inserts, ruby and sapphire check valves, PEEK |
Gradient Forming |
Binary gradient low pressure mixing and isocratic high pressure operation |
Other specifications |
as for the CE 4104 |
Binary Low Pressure Pump CE 4102
Noise |
±0.35 x 10- |
Drift |
±0.3 x 10- |
Dual Wavelength Operation |
Simultaneous measurements at 2 wavelengths Output of Absorbance ratio for the 2 wavelengths |
Noise, Dual Wavelength |
± 2 x 10- |
Drift, Dual Wavelength |
± 1 x 10- |
Programmed Operation |
Programs may be entered to change parameters, operating modes and select up to 6 different wavelengths in any time sequence. |
Printer Output |
Parallel printer port |
Dual Wavelength, Programmable UV Visible Detector CE 4200
Optical System |
Double beam with 1200 lines/mm grating monochromator |
Wavelength Range |
190- |
Wavelength Accuracy |
± 1nm |
Wavelength Precision |
± 0.1nm, single wavelength mode |
Optical Bandwidth |
8nm |
Straylight |
< .02%, 220nm |
Lamp |
Deuterium lamp with elapsed time indicator |
Absorbance Range |
0.001 to 2A full scale in 11 ranges |
Time Constant |
0.1, 0.2, 0.5, 1, 2, 5 and 10 seconds |
Display |
Four- |
Fast Number |
Entry By use of special number keys |
Event Marking |
From keypad or by external source |
Method Storage |
For up to 30 methods, security protected |
Second Order Filter |
Fast automatic insertion at 370nm |
Noise |
± 1 x 10- |
Drift |
± 1 x 10- |
Linearity |
Better than 1%, 0.001 – 2A |
Automatic Power- |
Pre- |
Sample Flow Cell |
8µL x 10mm pathlength – normal 4µL x 5mm pathlength Wetted surfaces PEEK, Teflon and Fused Silica Other cells available |
Refractive Index Sensitivity |
< ± 5 x 10- |
Flow Rate Sensitivity |
< ± 3.5 x 10- |
Outputs |
Two Absorbance outputs and Absorbance ratio to recorder. All data available to PowerStream System Manager. |
Inputs |
Event, autozero |
Size and Weight |
365 x 290 x 140mm, 17kg |
Power Requirements |
115V or 230V, 50/60Hz, 50VA |
UV-
Optical System |
Double beam |
Monochromator |
With 1200 l/mm holographic grating |
Wavelength Range |
190- |
Optical Bandwidth |
4nm – constant |
Digital Resolution |
1nm |
Wavelength Accuracy |
1nm |
Wavelength Reproducibility |
0.1nm |
Absorbance Range |
0 to 3A |
Scan Speeds |
Up to 1000nm/s |
Baseline Flatness |
± 0.002A over most of range |
Straylight |
<0.02% at 220nm and 340nm |
Noise |
< ±0.5 x 10–5 A at 230nm, 2s air test cell |
Drift |
< ±0.5 x 10–4 A at 230nm, using air test cell |
Calibration and Test |
Automatic at switch- |
Display |
Four line display of parameters, menus, prompts, wavelength, Absorbance etc. |
Number of Peak Scans |
Up to 100 peaks for any single elution |
Multiple Scans of a Peak |
Up to 8 scans of any peak |
Scan Trigger |
At start, set Absorbance value, point of inflection or at maximum |
Scan Storage |
Up to 100, password protected, unlimited with PowerStream |
Method Storage |
Up to 30 methods, password protected |
Size |
365 x 290 x 140mm, 17Kg |
Power Requirement |
115V or 250V, 50/60Hz, 50VA |
WaveQuest D.A.D. Ultra Fast Scanning Detector CE 4300
Measuring Ranges |
± 10- |
Sensitivity |
8 x 10- |
Noise |
8 x 10- |
Time constants |
0.1, 0.2, 0.5, 1, 2, 5, 10 seconds |
Cell volume |
9µL |
Outputs |
– |
Size and weight |
360 x 140 x 260mm, 9.5kg |
Power requirements |
100- |
Refractive Index Detector CE 4700
Light Source |
10W Xenon flash lamp, frequency programmable |
Detector |
Photomultiplier |
Excitation Monochromator |
200- |
Emission Monochromator |
200- |
Wavelength Scanning |
Excitation and emission independently programmable |
Sensitivity |
S/N >3000 for 4µg/L Anthracene in Methanol |
Analogue Outputs |
10mV, 100mV and 1V |
Power Requirements |
100/240V, 50/60Hz |
Fluorescence Detector Dual Monochromator CE 4500
Conductance Display Range |
0.01 – 5000µS. cm- |
Time Constant |
0.1, 0.2, 0.5, 1, 1.5, 2, 5s |
Autozero Range |
Typically up to 10,000µS. cm- |
Synchronous Detection Frequency |
5KHz |
Noise |
Less than ±1nS/cm, DI water, 1mL/min, 2s |
Drift |
Less than ±10nS/cm/h, DI water, 1mL/min, |
Cell Volume |
0.5µL |
Cell Body |
PEEK P1000 grade |
Electrodes |
316 stainless steel |
Cell Pressure Rating |
200psi |
Operating Temperature |
25 – 50ºC; 35ºC standard |
Temperature Precision |
± 0.01ºC |
Warm- |
10 minutes typical |
Method Storage |
Up to 100 with password protection |
Outputs |
0- |
Digital Control |
By PowerStream software |
Conductivity Detector CE 4710
Temperature Range |
5ºC to 70ºC (maximum 12ºC below ambient) |
Temperature and Set Point Readout |
3 digit, bright LED display |
Temperature Readout Resolution |
0.1ºC |
Temperature Stability |
± 0.01ºC |
Number of Columns |
3 up to 25cm long with pre- |
Heating Rate |
30 mins to 60ºC set point (ambient 25ºC) |
Stabilising Time |
Negligible when set point reached |
Leak Detection |
Vapour detector – adjustable shut down level |
Power Requirement |
50 Watts, 100- |
Size and Weight |
390H x 118W x 220D 6.4kg. |
Cooled and Heated Oven CE 4600
Number of flow channels |
4 (CE4040), 2 (CE 4020) |
Maximum Flowrate |
10mL/min |
Materials Contacting Solvents |
PEEK, glass filled PTFE, Teflon AF |
Gas removal |
To better than 1ppm at 1mL/min |
Solvent Degassers CE 4020 / CE 4040
Sampling system |
Headspace pressure, using dual concentric needle with internal air pump |
Capacity |
100 vial carousel |
Injection vial |
2 mL, 32 x 12 mm diameter |
Loop size |
10- |
Replicate injections per vial |
Up to 15 (dependent on loop size) |
Random access sampling |
Yes |
Priority sampling |
Yes |
Injection volume reproducibility |
Better than 0.2%, (typically <0.15%) |
Carryover |
Better than 0.005% with active needle wash Better than 0.03% with no needle wash |
Sample loop flush |
Operator selectable |
Wash station capacity |
12 mL |
Needle wash |
Dynamic wash system |
Injection valve |
Rheodyne |
Local control |
Press buttons and backlit LCD for data menu and instructions |
Remote control |
PC control using Cecil PowerStream software |
Communications |
RS232 and digital |
Ambient temperature range |
10°C to 35° C |
Power requirements |
110- |
Dimensions |
36 x 40 x 33 cm (l x d x h) |
Weight |
12 Kg |
AutoQuest Autosampler 4800-
Cecil Instruments policy is one of continuous development. We therefore reserve the right to change specifications without notice.