Features Top of the Page Baseline Stability: The Double beam monitoring ratio system enhances baseline stability. Excellent Resolution: The big-caliber light path…
sold out
Rp
Features

Top of the Page

  • Baseline Stability: The Double beam monitoring ratio system enhances baseline stability.
  • Excellent Resolution: The big-caliber light path enhances the instrument’s energy, reduces its noise and raises its resolution performance
  • 2 Cell Holder: Spectro UVD-2960 has 2 cell holder for reference (standard) and sample.
  • User-friendly light source: The light source performs an automatic interchange, selectable within the working range of the light source. The socket deuterium lamps and tungsten lamps facilitate light source replacement, simplify maintenance and reduce operation error.
  • Convenient Display: The large backlit LCD screen displays both photometric values and spectral curves.
  • Full use of Computer Technology:Being computer controlled with compatible with Windows XP, & and 8, using the new UVWin 6.0 UV-VIS application software, offering a wide range of uses and applications.
  • The key components are all adopted from the world famous manufacturer, such as deuterium lamp, silicon photodiode and holographic grating, which ensures the stabilization and credibility of the Instrument for extended life.
  • Computer System is optional (NOT INCLUDED).

Software Specifications

OUR NEW SOFTWARE UV-WIN 6.0
WITH 3D SPECTRA

Now all Labomed, Inc. split and double beam spectrophotometers with our newly developed software called UV-Win 6.0 can be used with Windows XP, Windows 7 and Windows 8. It is capable of testing more applications with its RS-232 and USB connections, and supports the data export of measured results to the PC and then, if required, a USB flash drive, when additional data storage is required. One of the new features is that it provides 3-D graphing of the spectral results.

Monoprocessor Built-in Application:

  • Photometric Measurement: Measuring transmittance or absorbance at the current wavelength together with K factor calculations.
  • Spectrum Scan: Carrying out scanning of transmittance or absorbance on the selected wavelength range together with peak-pick module.
  • Quantitative Determination: Regression of standard curves and direct determination concentration of samples.

PC Windows Application Software (RS-232 Interface) to link Spectro to computer and printer:

  • Photometric Measurement: Measuring the photometric values at 1-10 wavelengths together with mathematical calculations according to entered quotations.
  • Spectrum Scan: Producing Wavelength scans within the operating parameters on samples together with powerful data handling facilities.
  • Quantitative Determination: Determination of unknown concentration with methods of 1-3 wavelength quantitation, together with fitting of calibration curve of 1st ~ 4th order.
  • Kinetics: Recording curves of changing photometric values of samples against timecourse at the selected wavelengths together with powerful data handling facilities.
  • Output: With the Windows clipboard, the measured data and graphics can be copied to other applications software for reports.

 

Included Accessories

Top of the Page

2 Cell Holder

8 Optical Glass Cells 10mm.

2 Quartz Cells 10mm.

1 Dust cover

1 Instruction manual available in 18 different languages

1 Power cable

1 PC cable

1 Software CD for Windows 98/2000/XP/7

1 Software Operation Manual available in 18 different languages

1 Spare Tungsten Halogen Lamp

1 Block Light Cell

1 Extra fuse

DVD of installation and how to use the Spectro

Optional: Peltier Kinetic Test System

Optional: Sipper Flow Through System

 

 

Optional Accessories

  • Set of 2 performance testing filters (1 “E filter” for photometric accuracy test and 1 didymium filter for wavelength accuracy test)
  • Peltier constant temperature system (15 – 55 ºC Specify: Spectro UV-Vis Double)
  • Sipper flow through system (peristaltic pump and flow cell (Specify: Spectro UV-Vis Double)
  • Multi-purpose cell holder 20-30-40-50 Path Length

Top of the Page

Technical Specifications

Top of the Page
|

1) Wavelength Range: 190 nm – 1100 nm
– Spectral Bandwidth: 0.5, 1.0, 2.0 and 5.0 nm. (4 steps)
– Resolution: 0.5nm.
– Wavelength Display 0.1nm resolution
– Stray Light: >2.10Abs (200nm)
– Wavelength Accuracy: +0.3nm (with automatic wavelength correction)
– Wavelength Reproducibility: +0.2nm.
2) Photometric System: Double beam optical system
– Photometric Method: Transmittance, absorbance, energy and concentration
– Photometric Range: -0.3~3.0 Abs
– Photometric Accuracy: ±0.002Abs (0~0.5A)
±0.004Abs (0.5~1.0A)
±0.3%T (0~100%T)
– Photometric Reproducibility: ±0.001Abs (0~0.5A)
±0.002Abs (0.5~1.0A)
±0.15%T (0~100%T)
– Photometric Display: -9999 —- 9999
– Photometric Noise: ±0.001Abs (at 500nm, 2nm Spectral Bandwidth 0 Abs)
– Scanning Speed: 1400nm/min
– Baseline Flatness:  ±0.0015 Abs (200-1100nm)
– Baseline Stability: 0.0008Abs/h (2 hours warming up, 2nm Bandwidth, 500nm)
– Slew Rate of Wavelength: 3600nm/min
3) DNA/RNA Measurement:  
– Results Printout:
Printing of measured data by using any Printer with Parallel Port connection available.
4) Mainframe: Compact and standalone spectrophotometer mainframe
– Light Source: Socket Deuterium Lamp and Socket Tungsten Halogen Lamp.
– Detector: Double Beam
– Sample Chamber: 2 cell holder
– Display Liquid Crystal Display (LCD 320 x 240 dot matrix)
– Keypad: Touch soft keys.
– PC Interface: PC Interface: RS-232
– Size: 22″x16″x10”
– Weight: 55 Lb
– Voltage: 110 to 240V

 

Brosur

29. Labomed(USA)Spectro UV Vis VD 2960

Detail Produk

Kategori : ALAT LABORATORIUM
Features

Top of the Page

  • Baseline Stability: The Double beam monitoring ratio system enhances baseline stability.
  • Excellent Resolution: The big-caliber light path enhances the instrument’s energy, reduces its noise and raises its resolution performance
  • 2 Cell Holder: Spectro UVD-2960 has 2 cell holder for reference (standard) and sample.
  • User-friendly light source: The light source performs an automatic interchange, selectable within the working range of the light source. The socket deuterium lamps and tungsten lamps facilitate light source replacement, simplify maintenance and reduce operation error.
  • Convenient Display: The large backlit LCD screen displays both photometric values and spectral curves.
  • Full use of Computer Technology:Being computer controlled with compatible with Windows XP, & and 8, using the new UVWin 6.0 UV-VIS application software, offering a wide range of uses and applications.
  • The key components are all adopted from the world famous manufacturer, such as deuterium lamp, silicon photodiode and holographic grating, which ensures the stabilization and credibility of the Instrument for extended life.
  • Computer System is optional (NOT INCLUDED).

Software Specifications

OUR NEW SOFTWARE UV-WIN 6.0
WITH 3D SPECTRA

Now all Labomed, Inc. split and double beam spectrophotometers with our newly developed software called UV-Win 6.0 can be used with Windows XP, Windows 7 and Windows 8. It is capable of testing more applications with its RS-232 and USB connections, and supports the data export of measured results to the PC and then, if required, a USB flash drive, when additional data storage is required. One of the new features is that it provides 3-D graphing of the spectral results.

Monoprocessor Built-in Application:

  • Photometric Measurement: Measuring transmittance or absorbance at the current wavelength together with K factor calculations.
  • Spectrum Scan: Carrying out scanning of transmittance or absorbance on the selected wavelength range together with peak-pick module.
  • Quantitative Determination: Regression of standard curves and direct determination concentration of samples.

PC Windows Application Software (RS-232 Interface) to link Spectro to computer and printer:

  • Photometric Measurement: Measuring the photometric values at 1-10 wavelengths together with mathematical calculations according to entered quotations.
  • Spectrum Scan: Producing Wavelength scans within the operating parameters on samples together with powerful data handling facilities.
  • Quantitative Determination: Determination of unknown concentration with methods of 1-3 wavelength quantitation, together with fitting of calibration curve of 1st ~ 4th order.
  • Kinetics: Recording curves of changing photometric values of samples against timecourse at the selected wavelengths together with powerful data handling facilities.
  • Output: With the Windows clipboard, the measured data and graphics can be copied to other applications software for reports.

 

Included Accessories

Top of the Page

2 Cell Holder

8 Optical Glass Cells 10mm.

2 Quartz Cells 10mm.

1 Dust cover

1 Instruction manual available in 18 different languages

1 Power cable

1 PC cable

1 Software CD for Windows 98/2000/XP/7

1 Software Operation Manual available in 18 different languages

1 Spare Tungsten Halogen Lamp

1 Block Light Cell

1 Extra fuse

DVD of installation and how to use the Spectro

Optional: Peltier Kinetic Test System

Optional: Sipper Flow Through System

 

 

Optional Accessories

  • Set of 2 performance testing filters (1 “E filter” for photometric accuracy test and 1 didymium filter for wavelength accuracy test)
  • Peltier constant temperature system (15 – 55 ºC Specify: Spectro UV-Vis Double)
  • Sipper flow through system (peristaltic pump and flow cell (Specify: Spectro UV-Vis Double)
  • Multi-purpose cell holder 20-30-40-50 Path Length

Top of the Page

Technical Specifications

Top of the Page
|

1) Wavelength Range: 190 nm – 1100 nm
– Spectral Bandwidth: 0.5, 1.0, 2.0 and 5.0 nm. (4 steps)
– Resolution: 0.5nm.
– Wavelength Display 0.1nm resolution
– Stray Light: >2.10Abs (200nm)
– Wavelength Accuracy: +0.3nm (with automatic wavelength correction)
– Wavelength Reproducibility: +0.2nm.
2) Photometric System: Double beam optical system
– Photometric Method: Transmittance, absorbance, energy and concentration
– Photometric Range: -0.3~3.0 Abs
– Photometric Accuracy: ±0.002Abs (0~0.5A)
±0.004Abs (0.5~1.0A)
±0.3%T (0~100%T)
– Photometric Reproducibility: ±0.001Abs (0~0.5A)
±0.002Abs (0.5~1.0A)
±0.15%T (0~100%T)
– Photometric Display: -9999 —- 9999
– Photometric Noise: ±0.001Abs (at 500nm, 2nm Spectral Bandwidth 0 Abs)
– Scanning Speed: 1400nm/min
– Baseline Flatness:  ±0.0015 Abs (200-1100nm)
– Baseline Stability: 0.0008Abs/h (2 hours warming up, 2nm Bandwidth, 500nm)
– Slew Rate of Wavelength: 3600nm/min
3) DNA/RNA Measurement:  
– Results Printout:
Printing of measured data by using any Printer with Parallel Port connection available.
4) Mainframe: Compact and standalone spectrophotometer mainframe
– Light Source: Socket Deuterium Lamp and Socket Tungsten Halogen Lamp.
– Detector: Double Beam
– Sample Chamber: 2 cell holder
– Display Liquid Crystal Display (LCD 320 x 240 dot matrix)
– Keypad: Touch soft keys.
– PC Interface: PC Interface: RS-232
– Size: 22″x16″x10”
– Weight: 55 Lb
– Voltage: 110 to 240V

 