  • Semi-automated clinical chemistry analyzer
  • 60 programmable tests
  • Broad test menu
  • Full size screen and qwerty keyboard
  • No warm up time
  • Easy-to-train, operate and maintain
  • Bi-directional host connection
  • Up to 12 programmable wavelengths
Light Source Quartz-iodine lamp 12V-20W.
Wavelength Range – Optical unit with 12 position filter wheel
– 340, 405, 505, 546, 578, 620 nm standard installed
– 6 positions for optional filters.
Photometric Range -0.1 to 2.3 Absorbance
Resolution 0.001 Abs.
Detector Photo diode (320-1000 nm).
Blanking Automatic zero setting.
Operator Interface – Membrane keyboard, for direct function and alpha-numeric entry
– Optional external keyboard
– High contrast graphical LCD display
– Real time clock, 24 hours system.
Measurement Procedures – Kinetic measurement with linearity check
– Kinetic, with linearity check and sample slope blank
– Two point kinetic, with or without reagent blank
– End point, with or without reagent blank
– Bichromatic end point, with or without reagent blank
– End point, with sample blank and with or without reagent blank.
Multiple Testing – Up to nine replicates
– Means, SD and CV.
Measurement Time – Programmable, 2 to 998 seconds for kinetic and two point type of tests
– For end point fixed at 2 seconds.
Delay Time Programmable, 0 to 999 seconds.
Parameter Setting – Method name
– Measurement mode
– Wavelength 1 and 2
– Aspiration volume
– Measurement delay
– Measurement time
– Factor
– Concentration standards
– Reagent blank y/n
– Sample blank y/n
– Units for results
– Levels for flagging
– Curve fit y/n
– Linearity check.
Calibration – Factor, one-point, two-point and multi-point
– Automatic on 1 standard (linear mode)
– Automatic on up to 10 standards (non-linear mode).
Quality Control – Two controls per test
– QC survey of last 30 control measurements
– Levey Jenning plot
– High/low flags.
Flowcell Metal, with quartz windows, measuring volume 30 µL.
Temperature Control – By means of Peltier elements
– Fixed temperature at 37°C.
Aspirator System – Internal pump of bellows type, driven by stepper motor:
– Back panel connection for waste
– Aspiration volume programmable.
Printer – Internal matrix printer
– Normal paper
– External printer port available.
Signal Interface – Centronics type parallel port
– RS 232 type serial port
– PS 2 type port for external keyboard.
Standards and Regulations – CE -IVD
– CB
– UL.
Dimensions and Power Requirements – 40 x 17 x 36,6 cm (W x H x D)
– Weight: 8,5 kg.
– 100-240 VAC nominal, 50/60 Hz
– Battery back-up to retain data

BROSUR

vital-microlab300-2010

Produk Pernah Dilihat

Detail Produk

Kategori : LAIN-LAIN

 

  • Semi-automated clinical chemistry analyzer
  • 60 programmable tests
  • Broad test menu
  • Full size screen and qwerty keyboard
  • No warm up time
  • Easy-to-train, operate and maintain
  • Bi-directional host connection
  • Up to 12 programmable wavelengths
Light Source Quartz-iodine lamp 12V-20W.
Wavelength Range – Optical unit with 12 position filter wheel
– 340, 405, 505, 546, 578, 620 nm standard installed
– 6 positions for optional filters.
Photometric Range -0.1 to 2.3 Absorbance
Resolution 0.001 Abs.
Detector Photo diode (320-1000 nm).
Blanking Automatic zero setting.
Operator Interface – Membrane keyboard, for direct function and alpha-numeric entry
– Optional external keyboard
– High contrast graphical LCD display
– Real time clock, 24 hours system.
Measurement Procedures – Kinetic measurement with linearity check
– Kinetic, with linearity check and sample slope blank
– Two point kinetic, with or without reagent blank
– End point, with or without reagent blank
– Bichromatic end point, with or without reagent blank
– End point, with sample blank and with or without reagent blank.
Multiple Testing – Up to nine replicates
– Means, SD and CV.
Measurement Time – Programmable, 2 to 998 seconds for kinetic and two point type of tests
– For end point fixed at 2 seconds.
Delay Time Programmable, 0 to 999 seconds.
Parameter Setting – Method name
– Measurement mode
– Wavelength 1 and 2
– Aspiration volume
– Measurement delay
– Measurement time
– Factor
– Concentration standards
– Reagent blank y/n
– Sample blank y/n
– Units for results
– Levels for flagging
– Curve fit y/n
– Linearity check.
Calibration – Factor, one-point, two-point and multi-point
– Automatic on 1 standard (linear mode)
– Automatic on up to 10 standards (non-linear mode).
Quality Control – Two controls per test
– QC survey of last 30 control measurements
– Levey Jenning plot
– High/low flags.
Flowcell Metal, with quartz windows, measuring volume 30 µL.
Temperature Control – By means of Peltier elements
– Fixed temperature at 37°C.
Aspirator System – Internal pump of bellows type, driven by stepper motor:
– Back panel connection for waste
– Aspiration volume programmable.
Printer – Internal matrix printer
– Normal paper
– External printer port available.
Signal Interface – Centronics type parallel port
– RS 232 type serial port
– PS 2 type port for external keyboard.
Standards and Regulations – CE -IVD
– CB
– UL.
Dimensions and Power Requirements – 40 x 17 x 36,6 cm (W x H x D)
– Weight: 8,5 kg.
– 100-240 VAC nominal, 50/60 Hz
– Battery back-up to retain data