NCT-100 Air Puff Non-Contact Tonometer VISIONSTAR
NCT-100 Air Puff Non-Contact Tonometer VISIONSTAR

NCT-100 Air Puff Non-Contact Tonometer VISIONSTAR

5 (1 votes)

share

NCT-100 Air Puff Non-Contact Tonometer Model: NCT-100 NCT-100 is a non contact tonometer, using puff of air to measure eye…
sold out
Rp

NCT-100 Air Puff Non-Contact Tonometer
Model: NCT-100
NCT-100 is a non contact tonometer, using puff of air to measure eye pressure. This pulse air tonometer is accurate, easy and fast to operate, and you can get a measurement result within 10 seconds. Non contact air puff tonometer will also prevent infections and corneal injuries during the measurement.

Product features:
NCT-100 air puff non-contact tonometer utilizes image control and feature recognition for auto 3-D positioning of xyz with reliable judgment and measurement results, and easy to operate. The air puff non-contact tonometer can be used to measure intraocular pressure (IOP) and corneal thickness.
Performance Features:
1. Auto 3-D positioning of xyz results in precise and reliable measurement.
2. Full-auto measurement for both right and left eye data without manual switch.
3. Easy to operate the tonometer with color touch monitor.
4. Stable data of IOP through soft air measurement .
5. To compensate corneal thickness measurement of IOP.

Intraocular pressure (IOP) measuring range

1mmHg~30mmHg /1mmHg~60mmHg ( precision of 1mmHg)

Measuring system

dual sensor system of light and pressure

Working distance

≥11mm

R/L

automatic detection and display

Measuring result

10 times per eye; 3 times result printing per eye

Recording

build-in printer

Measuring mode

auto/manual

Focus

when luminous spot is in the focus frame, 2 modes can be chosen.

auto mode: auto intraocular pressure measurement

manual mode: when it’s good focus, the

frame will turn yellow into green, and click

to start the measurement

Error indication

if the measurement signal is weak, the IOP will be enclosed by ( ), or display “ERR ”

Safety limit button

install measurement for minimum distance between head and patient

Safety functions

the distance between air nozzle and cornea

is controlled in preset range(such as 11mm);

it will stop going forward when the cornea is

too closed to air head.

Movement range

≥30mm(front to back)/ 90mm(left to right)/ 30mm(vertical)

Jaw layer vertical movement

0~65mm with under jaw layer

Display mode

10.1-inch HDMI color LED touch monitor

Output port

USB2.0

Working platform

electric elevating platform

Weight

19.7kg

size

380 mm (L) x 460mm (W) x 505mm (H)

Power supply

220V/50HZ

 

Detail Produk

Kategori : ALAT KESEHATAN

NCT-100 Air Puff Non-Contact Tonometer
Model: NCT-100
NCT-100 is a non contact tonometer, using puff of air to measure eye pressure. This pulse air tonometer is accurate, easy and fast to operate, and you can get a measurement result within 10 seconds. Non contact air puff tonometer will also prevent infections and corneal injuries during the measurement.

Product features:
NCT-100 air puff non-contact tonometer utilizes image control and feature recognition for auto 3-D positioning of xyz with reliable judgment and measurement results, and easy to operate. The air puff non-contact tonometer can be used to measure intraocular pressure (IOP) and corneal thickness.
Performance Features:
1. Auto 3-D positioning of xyz results in precise and reliable measurement.
2. Full-auto measurement for both right and left eye data without manual switch.
3. Easy to operate the tonometer with color touch monitor.
4. Stable data of IOP through soft air measurement .
5. To compensate corneal thickness measurement of IOP.

Intraocular pressure (IOP) measuring range

1mmHg~30mmHg /1mmHg~60mmHg ( precision of 1mmHg)

Measuring system

dual sensor system of light and pressure

Working distance

≥11mm

R/L

automatic detection and display

Measuring result

10 times per eye; 3 times result printing per eye

Recording

build-in printer

Measuring mode

auto/manual

Focus

when luminous spot is in the focus frame, 2 modes can be chosen.

auto mode: auto intraocular pressure measurement

manual mode: when it’s good focus, the

frame will turn yellow into green, and click

to start the measurement

Error indication

if the measurement signal is weak, the IOP will be enclosed by ( ), or display “ERR ”

Safety limit button

install measurement for minimum distance between head and patient

Safety functions

the distance between air nozzle and cornea

is controlled in preset range(such as 11mm);

it will stop going forward when the cornea is

too closed to air head.

Movement range

≥30mm(front to back)/ 90mm(left to right)/ 30mm(vertical)

Jaw layer vertical movement

0~65mm with under jaw layer

Display mode

10.1-inch HDMI color LED touch monitor

Output port

USB2.0

Working platform

electric elevating platform

Weight

19.7kg

size

380 mm (L) x 460mm (W) x 505mm (H)

Power supply

220V/50HZ

 

Tidak ada produk berkaitan.

Tidak ada produk popular.