Spectro 2000RS Visible Spectrophotometer  With 4 automatic cell holder
Spectro 2000RS Visible Spectrophotometer  With 4 automatic cell holderSpectro 2000RS Visible Spectrophotometer  With 4 automatic cell holder

Spectro 2000RS Visible Spectrophotometer With 4 automatic cell holder

5 (1 votes)

share

Features Top of the Page Automatic self adjustment 4 Automatic cell holder Auto select wavelength Auto Zero ABS and 100%T.…
sold out
Rp
Features

Top of the Page

  • Automatic self adjustment
  • 4 Automatic cell holder
  • Auto select wavelength
  • Auto Zero ABS and 100%T.
  • Auto A/T/C and Factor.
  • Auto Escape and back-up.
  • Interface RS232C port for use with computer & printer.
  • Built-in printer.
  • Switch for 110V 60Hz. and 220V 50Hz.
  • F.D.A. Licensed.
  • High photometric accuracy for smooth spectral band pass.
  • Reliable stability for reliable testing
  • Wide continuous wavelength range for test flexibility
  • Easy to change Tungsten Halogen lamp
  • COMPETITIVE PRICE.
  • Computer System is optional (NOT INCLUDED).

Included Accessories

Top of the Page

  • 4 square glass cells 10mm
  • 1 mounted multiple 4 cell holder
  • Dust cover
  • Cable
  • Instruction book
  • Optional: Large cell holder 20-30-40 and 50mm

Optional Accessories

  • Multi-purpose cell holder for long path cells (Specify Spectro 2000 RS
    or Spectro 2000 RSP)
  • Peltier constant temperature control system (single cell, 15-55ºC)
  • Square cuvette (optical glass), 10mm path length
  • Micro and semi-micro cells, set of 2 with covers, useable for wavelengths
    from 325 – 1100nm. (Specify sample volume: 0.5, 0.75, 1.00 or 1.25ml)
  • Rectangular long path cell (optical glass. Specify 20, 30, 40 or 50mm path
    length)
  • Software for Windows 95/98/XP/7 Includes  RS232C cable, operator’s manual.
    (Specify: Spectro 23 RS)

 

Top of the Page

  • Constant temperature system for kinetic testing: three square cell holders
    and front panel. (Specify: Spectro 23 or Spectro 23 RS)
  • Flow through system (peristaltic pump and flowcell)
  • Multi-purpose cell holder for long path (20 – 50mm) rectangular cells
  • Holder for test tube cuvettes, 10 – 25mm diameter

Technical Specifications

Top of the Page

Optical System: Single Beam
Wavelength Range: 325-1100nm.
Light Source: Tungsten-Halogen Lamp
Detector: Silicon Photodiode
Wavelength Distance: 1nm.
Wavelength Accuracy: + 1 nm.
WavelengthReproducibility: 0.5 nm.
Photometric Range: 0.0%~150.0%T
-0.175A~2.000A
0-6000C
Spectral Band Pass: 6 nm.
Transmittance Reproducibility: 0.3% (T)
Transmittance Range: 0-125% (T)
Absorption Range: 0-1999% (A)
Concentration Range: 0-2000
Photometric Accuracy: +0.5 (T) +0.004 A.
Monochromator Grating Mirror: 1200 lines/mm.
Readout: LCD 2 line
Power Supply Switching: 110V./60 Hz. and 220V./50Hz.
Dimensions: 16″ x 14″ x 8″ (Inches).
Net Weight: 20 lb. (9 kg.)
Operating System: Windows 95/98/XP/7

 

Brosur

18. Labomed(USA)Spectro 2000 RS and Spectro 2000 RSP,320-1100nm

Detail Produk

Kategori : LAIN-LAIN
Features

Top of the Page

  • Automatic self adjustment
  • 4 Automatic cell holder
  • Auto select wavelength
  • Auto Zero ABS and 100%T.
  • Auto A/T/C and Factor.
  • Auto Escape and back-up.
  • Interface RS232C port for use with computer & printer.
  • Built-in printer.
  • Switch for 110V 60Hz. and 220V 50Hz.
  • F.D.A. Licensed.
  • High photometric accuracy for smooth spectral band pass.
  • Reliable stability for reliable testing
  • Wide continuous wavelength range for test flexibility
  • Easy to change Tungsten Halogen lamp
  • COMPETITIVE PRICE.
  • Computer System is optional (NOT INCLUDED).

Included Accessories

Top of the Page

  • 4 square glass cells 10mm
  • 1 mounted multiple 4 cell holder
  • Dust cover
  • Cable
  • Instruction book
  • Optional: Large cell holder 20-30-40 and 50mm

Optional Accessories

  • Multi-purpose cell holder for long path cells (Specify Spectro 2000 RS
    or Spectro 2000 RSP)
  • Peltier constant temperature control system (single cell, 15-55ºC)
  • Square cuvette (optical glass), 10mm path length
  • Micro and semi-micro cells, set of 2 with covers, useable for wavelengths
    from 325 – 1100nm. (Specify sample volume: 0.5, 0.75, 1.00 or 1.25ml)
  • Rectangular long path cell (optical glass. Specify 20, 30, 40 or 50mm path
    length)
  • Software for Windows 95/98/XP/7 Includes  RS232C cable, operator’s manual.
    (Specify: Spectro 23 RS)

 

Top of the Page

  • Constant temperature system for kinetic testing: three square cell holders
    and front panel. (Specify: Spectro 23 or Spectro 23 RS)
  • Flow through system (peristaltic pump and flowcell)
  • Multi-purpose cell holder for long path (20 – 50mm) rectangular cells
  • Holder for test tube cuvettes, 10 – 25mm diameter

Technical Specifications

Top of the Page

Optical System: Single Beam
Wavelength Range: 325-1100nm.
Light Source: Tungsten-Halogen Lamp
Detector: Silicon Photodiode
Wavelength Distance: 1nm.
Wavelength Accuracy: + 1 nm.
WavelengthReproducibility: 0.5 nm.
Photometric Range: 0.0%~150.0%T
-0.175A~2.000A
0-6000C
Spectral Band Pass: 6 nm.
Transmittance Reproducibility: 0.3% (T)
Transmittance Range: 0-125% (T)
Absorption Range: 0-1999% (A)
Concentration Range: 0-2000
Photometric Accuracy: +0.5 (T) +0.004 A.
Monochromator Grating Mirror: 1200 lines/mm.
Readout: LCD 2 line
Power Supply Switching: 110V./60 Hz. and 220V./50Hz.
Dimensions: 16″ x 14″ x 8″ (Inches).
Net Weight: 20 lb. (9 kg.)
Operating System: Windows 95/98/XP/7

 