Water Purification System Labocon
Water Purification System LaboconWater Purification System Labocon

Water Purification System Labocon

5 (1 votes)

share

Electro Deionized EDI-DOT-10 Labocon Electro Deionized Series is a superior choice for production of Deionized water for general grade experiments.…
sold out
Rp

Electro Deionized EDI-DOT-10

Labocon Electro Deionized Series is a superior choice for production of Deionized water for general grade experiments. The single stage RO water’s ion rejection rate is more than 96%, the deionized water’s resistivity is stable at grade II pure water with resistivity > 5MΩ.cm (25 ℃ ), TOC<30ppb, and the lowest running cost.

It completely meets the requirements of general chemical or biological experiments for pure water, and is up to the standard of ISO 3696(Type II), ASTM D1193 (Resistivity of type II and TOC), and the requirements for pure water of CLSI (NCCLS) clinical laboratory, GB/T6682, America, Europe, Japan’s pharmacopeia.

Model No.

EDI-DOT-10

EDI-DOT-10-PB

Output(25℃)* 10 litres/hour

Pure water outlet 2: reverse osmosis water, deionized water

EDI water quality Resistivity >5MΩ.cm TOC* <30ppb

Silicone rejection rate >99.9%

Bacteria NA <0.1cfu/ml

Particle(>0.1μm) NA <1/ml

RO water quality Ion rejection rate 96%-99% (new RO membrane)

Organic rejection rate >99%, when MW>200

Dalton Particles and bacteria rejection rate >99%

Feed water requirements Tap water, temperature:5- 45℃,pressure:1.0-4.0Kgf/cm2

Dimension 500×360×540mm

Weight 20Kg

Electrical requirements AC110-240V, 50/60Hz Power 120W

Standard configuration Main body (Including 1 set of cartridge)+20 litres pressure tank

*The value will be influenced by temperature and feed water’s quality

edi-deionized-water

Produk Pernah Dilihat

Detail Produk

Kategori : ALAT LABORATORIUM

Electro Deionized EDI-DOT-10

Labocon Electro Deionized Series is a superior choice for production of Deionized water for general grade experiments. The single stage RO water’s ion rejection rate is more than 96%, the deionized water’s resistivity is stable at grade II pure water with resistivity > 5MΩ.cm (25 ℃ ), TOC<30ppb, and the lowest running cost.

It completely meets the requirements of general chemical or biological experiments for pure water, and is up to the standard of ISO 3696(Type II), ASTM D1193 (Resistivity of type II and TOC), and the requirements for pure water of CLSI (NCCLS) clinical laboratory, GB/T6682, America, Europe, Japan’s pharmacopeia.

Model No.

EDI-DOT-10

EDI-DOT-10-PB

Output(25℃)* 10 litres/hour

Pure water outlet 2: reverse osmosis water, deionized water

EDI water quality Resistivity >5MΩ.cm TOC* <30ppb

Silicone rejection rate >99.9%

Bacteria NA <0.1cfu/ml

Particle(>0.1μm) NA <1/ml

RO water quality Ion rejection rate 96%-99% (new RO membrane)

Organic rejection rate >99%, when MW>200

Dalton Particles and bacteria rejection rate >99%

Feed water requirements Tap water, temperature:5- 45℃,pressure:1.0-4.0Kgf/cm2

Dimension 500×360×540mm

Weight 20Kg

Electrical requirements AC110-240V, 50/60Hz Power 120W

Standard configuration Main body (Including 1 set of cartridge)+20 litres pressure tank

*The value will be influenced by temperature and feed water’s quality